Toshiba RAS-3M18S3AV-E Service Manual page 37

Split type
Hide thumbs Also See for RAS-3M18S3AV-E:
Table of Contents

Advertisement

・RAS-2M18S3AV-E , -A , -TR
・RAS-2M14S3AV-E , -TR
Connecting pipe
Thickness : 0,8mm
dia.9,52
Pressure
measurement
Gauge attaching port
connecting port
Packed valve
(Gas side)
(dia.9,52)
TS
NOTE :
• You need not add refrigerant if the piping length is
• Connection of only one indoor unit is unavailable. Two indoor units should be connected.
Temp. measurement
To
B room
Packed valve
(Gas side)
(dia.9,52)
TGb
TGa
High pressure
switch
Temp.measurement
T2
T1
Indoor unit A
Evaporator
Cross flow fan
TA
Connecting pipe
Thickness : 0,8mm
dia.6,35
Sectional shape
of heat insulator
TD
Compressor
DA136A1T-40N
Propeller fan
TO
Outdoor unit
30
m or less.
- 37 -
FILE NO. SVM-15102
TC
To
B room
Packed valve
(Liquid side)
(dia.6,35)
Pulse motor valve
at liquid side
(dia.1,6)
TE
Refrigerant amount : 1,32kg (R410A)
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
Per 1 unit
Max. : 20m
Min. : 2m
Total
Max. : 30m
Packed valve
(Liquid side)
(dia.6,35)