Daikin FTK-J series Technical Manual page 9

Inverter single split series
Table of Contents

Advertisement

Outdoor Clearance
If the condensing unit is operated in an atmosphere containing oils (including machine
oils), salt (coastal area), sulphide gas (near hot spring, oil refi nery plant), such as
• Where a wall or order obstacle is in the path of outdoor unit's intake or exhaust airfl ow, follow the
installation guidelines below.
• For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.
Model: RK25/35FXV19, RXN25/35FXV1
Wall facing one side
More than 50
More than 100
1200 or
less
Side View
Model: RK50/60CXV19, RXN50/60CXV1
A
AIR INLET
ALL MODELS
Minimum Distance
substances may lead to failure of the unit.
Wall facing two side
More than 50
Wall facing three side
More than 50
B
AIR DISCHARGE
A
300 mm
More than 150
More
than 100
Top View
More than 150
More than 300
Top View
C
SERVICE SPACE
AIR INLET
B
C
1000 mm
300 mm
Application Information
More than 50
Unit : mm
D
D
500 mm
7