Cautions When Connecting/Disconnecting The Hv Connector - Hitachi C47-WD7000 Service Manual

Table of Contents

Advertisement

CAUTIONS WHEN CONNECTING/DISCONNECTING THE HV CONNECTOR

Perform the following when the
HV connector (anode connector)
is removed or inserted for PRT
replacement, etc.
O
L
Fig. 3 Remove the anode connector
During Insertion
1. Please refer to direction for insertion as shown in Fig. 4 (L position). Insert connector until "CLICK" sound is heard.
2. Make sure the connector is pressed right in, so that it has a good contact with the spring.
3. Confirm the contact by pulling the connector slightly. (Don't pull hard because it may damage the connector).
4. Cover the high voltage output by carefully pushing silicon cover onto it. (Don't turn the connector).
(REMARK)
1. Make sure the silicon cover is
covering the high voltage output.
O
L
L
During Removal
1. Roll out silicon cover from FBT's contact area slowly.
2. While turning the connector about 90 degrees following the
arrow (from L position to O position), push the connector
slightly towards the case. (Fig .3)
3. Remove the connector slowly by pulling it away from the
case.
Fig. 4 Insert the anode connector
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C50-fd7000C43-fl7000C57-wd7000C43-fd7000

Table of Contents