Cautions When Connecting/Disconnecting The Hv Connector - Hitachi 53SWX10B Service Manual

Projection color television
Hide thumbs Also See for 53SWX10B:
Table of Contents

Advertisement

CAUTIONS WHEN CONNECTING / DISCONNECTING THE HV CONNECTOR
Perform the following when the
HV connector (anode connector)
is removed or inserted for CPT
replacement, etc.
PUSH
PUSH
During Insertion
1.
Please refer to direction for insertion as shown in Fig. B (L position). Insert connector until "CLICK" sound is heard.
2.
Make sure the connector is pressed right in, so that it has a good contact with the spring.
3.
Confirm the contact by pulling the connector slightly. (Don't pull hard because it may damage the connector).
4.
Cover the high voltage output by carefully pushing silicon cover onto it. (Don't turn the connector).
(REMARK)
1.
Make sure the silicon cover is
covering the high voltage output.
Deflection P.W.B.
Fig. A
3.
Remove the connector slowly
by pulling it away from the
case.
FBT
During Removal
1.
Roll out silicon cover from FBT's contact area slowly.
2.
While turning the connector about 90 degrees
following the arrow (0 position), push the connector
slightly towards the case. (Fig. A)
Silicon cover
Wing
L Position
Silicon Cover
less than 1mm
12
Anode
connector
Wing
L Position
Fig. B