Breakdown Self Diagnosis Function - Panasonic CS-E15DB4EW Service Manual

Philips air conditioner user manual
Hide thumbs Also See for CS-E15DB4EW:
Table of Contents

Advertisement

CS-E15DB4EW CU-E15DBE / CS-E18DB4EW CU-E18DBE / CS-E21DB4ES CU-E21DBE
1. Relationship between the condition of the air conditioner and pressure and electric current
Condition of the air
conditoner
Insufficient refrigerant
(gas leakage)
Clogged capillary tube
or Strainer
Short circuit in the
indoor unit
Heat radiation
deficiency of the
outdoor unit
Inefficient compression
• Carry on the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.

12.2. Breakdown Self Diagnosis Function

Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of
three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below
breakdown diagnosis method:
• Press "CHECK" button at remote control continuously for more than five seconds to turn on the diagnosis mode, "H11" will be
displayed at remote control.
• By pressing the TMER "
displayed.
• If error code displayed matches the error code saved in unit memory (abnormality detected), "beep, beep, beep...." sounds will
be heard for 4 seconds and Power LED will light on. Otherwise, one "beep" sound is heard.
If "CHECK" button is press again or without any operation for 30 seconds, the diagnosis mode will turn off.
Cooling Mode
Low Pressure
High Pressure
" button once, next error code will be displayed; press "V" button once, previous error code will be
Electric current
Low Pressure
during operation
68
Heating Mode
High Pressure
Electric current
during operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-e15dbeCs-e18db4ewCu-e18dbeCs-e21db4esCu-e21dbe