CONTROL POINTS

Control points and control values
Control points are presented in numerical order 0...28. Study all the control points
to ensure the optimum possible operation of the door. Adjust the functions
ensuring the safety clutch does not slip.
Control point
Control
n:o
value
3...60
3...60
0...60
1...10
0...15
1...10
1...10
0...60
1...10
1...10
1...10
0...10
o
max. 100
Description
Opening direction: Starting point of final speed
Door open position
Closing direction: Starting point of final speed
Operator's force (Sealed)
Delay time for inside impulse
Opening speed
Opening direction: Final speed (Sealed)
Outside impulse: Hold open time
Operator sensitivity (Sealed)
Closing speed
Closing direction: Final speed
Lock-up force (Sealed)
11
Factory
setting
40
48
10
5
5
7
5
8
7
5
4
0