Download Print this page

CookTek CKT0044 Owner's Manual page 13

Advertisement

In the event of a Possible Malfunction, your CookTek MagnaWave Buffet Wok will display
an Error Code on the LCD Information Center and the unit will beep the number of
times indicated by the error. Please consult the following table when encountering an
Error Code. To reset the error conditions remove the pan from the unit and press the
Power button or unplug the unit.
Error
Error Cause
Code
1
Shorted RTD
2
Opened RTD
3
Over current (peak)
4
Open TCO
5
Air flow blocked
6
High line voltage
7
Hardware Failure
8
Zero cross failure
9
Clock corrupt
10
Pan RTD failure
11
Tag Communication
failure
12
RFID Reader Failure
14
User Interface Error
16
Critical Error
OWNER'S MANUAL INSTALLATION AND OPERATION
Displayed Message
Temperature sensor failed.
Call dealer.
Temperature sensor failed.
Call dealer
Incompatible Pan.
Overheating. Check Airflow.
Unplug, let cool.
Airflow blocked.
Clean grease filter.
Input voltage too high.
Check mains voltage.
Call dealer for service.
Call dealer for service
Reset clock.
Pan temperature sensor
failed.
Reposition pan & cycle power. Ensure the RFID tag on the pan
Call dealer for service.
Cycle power.
Call dealer for service.
Troubleshooting
Service Required
Remove any pans from Buffet
Wok surface and let unit cool.
Then turn unit off, then on.
If problem was temperature
related, the unit will return to
normal operation, otherwise
service is required.
Try different cookware.
Service may be required
Check airflow. Clear air vents.
Listen for fan operation.
Check to ensure the grease filter
is clean and dry. Make certain
there are no foreign objects
blocking air flow. Check the air
filter to ensure that the arrow on
the filter is pointing up.
To reset, unplug unit, wait 5
seconds, and plug in again.
If problem persists, have an
electrician monitor the line
voltage.
Service required.
Turn unit off, then on. Plug unit
into outlet on different circuit
breaker. If problem persists,
service is required on device.
Reset Clock
RFID Pan needs repair.
Service needed for Pan
is properly located
Service Required
Service Required
Service Required
11