Restore Factory Settings - HomeMatic HmIP-ASIR Mounting Instruction And Operating Manual

Alarm siren
Table of Contents

Advertisement

Available languages

Available languages

1x orange
and 1 x green
lighting
9

Restore factory settings

The factory settings of the device can be re-
stored. If you do this, you will lose all your set-
tings.
To restore the factory settings of the alarm siren, please
proceed as follows:
Rotate the device anti-clockwise in order to re-
move it from the mounting plate (see figure 6).
Remove one battery from the battery compart-
ment (D).
Please wait a minute.
Insert the battery ensuring that the polarity is
correct (see figure 7) while pressing and holding
down the system button (B) for 4 seconds at the
same time, until the LED quickly starts flashing or-
ange (see figure 5).
Release the system button again.
Press and hold down the system button again for
4 seconds, until the status LED lights up green.
Release the system button to finish the proce-
dure.
Test display
Restore factory settings
Once the test dis-
play has stopped,
you can continue.
39