When malfunctions occur

6.
Malfunction
Lift
does not
function
The lift does
not start up
when the
platform
is folded down
and occupied.
Only for
Automatic
system:
Lift does not
fold down
automatically
If you cannot rectify the malfunction yourself, please contact your customer service.
7.
Acoustical warning signal
Duration
Pause
[sec]
[sec]
0.1
5.0
Battery undervoltage
(Also see 4.2)
0.1
0.5
Acoustical travel warning
2x short
4.0
Excess temperature of
motor/electronics
or fuse defective
Operator manual Konstanz STG/ASA
possible cause
Is the key on the operator panel
set to -I-, and for the others
to -0- or removed ?
Are all EMERGENCY-OFF
switches
unlocked?
Is the main switch for the lift
Set to -I- ?
Battery defective or completely
discharged
Safety catch is engaged
Are the safety gates
in a horizontal position ?
Are the drive-up flaps and the
Safety bar (if present)
freely mobile ?
Load carrying capacity exceeded Reduce the weight
Are all key switches set
to -0- except on the control
station
selected by you ?
Are the batteries in the sender in
order for radio-operated
control stations?
Reason
19/20
measure
Switch the key switch
correctly (see 4.5 or.4.6)
Unlock the EMERGENCY-OFF
switch by
turning or pulling
(depending on design)
Activate main switch
(see 4.1)
Replace battery (technical
personnel)
Inform a technical specialist
Activate the safety gates one more
time,
possibly move them
slightly up or down
Press the drive-up flaps and the
safety
Bar
lightly outwards
Drive in the opposite direction
Switch the key switch
correctly (see 4.5 or 4.6)
Replace batteries in the sender
Rectification
Drive to the charging station and
charge the batteries
--
Continued travel after about 5min.
cooling time is possible (for
insufficient cooling extend the cooling
time by an additional 5 min.
Version 8.0 (01/2010)