Samsung DMR78AHS/XAC Service Manual page 46

Table of Contents

Advertisement

4. Troubleshooting
Error type
Error mode
Half load error
PE
Overflow error
oE
4-8
Checking Method
5. Remove the Distributor Motor and check the
operation of the motor.
(Use t8 service inspection mode .)
Normal: The motor rotates normally.
6. Check the position sensing operations when turning
the Micro Switch on and off.
(Use t8 service inspection mode.)
Check the conduction between the maroon
wire and the pink wire.
Micro switch On: Short
Micro switch Off: Open
1. Check the connections for the Overflow Sensor
connector.
2. Check whether the Inlet Valve operates normally.
Use t1 service inspection mode.
3. Check whether water is supplied (even small
amounts) in the intervals when the Inlet Valve is not
operating.
Corrective actions
- Faulty: Replace the Distributor Motor.
- Faulty: Replace the Micro Switch for sensing positions.
- Normal: Replace the valve distributor and CAM switch.
Micro Switch Off
(open)
Micro Switch
push: On (short)
- Reconnect the Overflow Sensor connector.
- See "4E Error".
- Remove foreign material from the Inlet Valve.
- If you cannot remove the foreign material from the Inlet Valve, replace it.