Samsung AE***JXYDGH Series Installation Manual page 34

Air to water heat pump mono outdoor unit
Table of Contents

Advertisement

Nominal dimensions for
cable [mm
(inch)]
2
Nominal dimensions for
screw [mm(inch)]
Standard dimension
[mm(inch)]
B
Allowance [mm(inch)]
Standard dimension
[mm(inch)]
D
Allowance [mm(inch)]
Standard dimension
[mm(inch)]
d1
Allowance [mm(inch)]
E
Min. [mm(inch)]
F
Min. [mm(inch)]
L
Max. [mm(inch)]
Standard dimension
[mm(inch)]
d2
Allowance [mm(inch)]
t
Min. [mm(inch)]
f Connect the rated cables only.
f
f Connect using a driver which is able to apply the rated torque to the screws.
f
f If the terminal is loose, fire may occur caused by arc. If the terminal is connected too firmly, the terminal may be
f
damaged.
M4
M5
• When connecting cables, you can connect the cables to the electrical part or connect them through the holes
below depending on the spot.
CAUTION
• Run transmission wiring between the indoor and outdoor units through a conduit to protect against external
forces, and feed the conduit through the wall together with refirgerant piping.
• Remove all burrs at the edge of the knock-out hole and secure the cable to the outdoor knock-out using lining
and bushing with an electrical insulation such as rubber and so on.
• Must keep the cable in a protection tube.
• Keep distances of 50mm or more between power cable and communication cable.
• When the cables are connected through the hole, remove the Plate bottom.
EHS MONO_ODU_IM_05387A-01_BOOK.indb 33
4/6 (0.006/0.009)
10 (0.01) 16 (0.02)
4 (3/8)
8 (3/16)
8 (3/16)
8 (3/16)
9.5 (3/8) 15 (9/16) 15 (9/16)
(10/16)
±0.2
±0.2 (±0.007)
(±0.007)
(±0.007)
5.6 (1/4)
7.1 (1/4)
9 (3/8)
+0.3
+0.3 (+0.011)
(+0.011)
(+0.011)
-0.2 (-0.007)
-0.2
(-0.007)
(-0.007)
3.4 (1/8)
4.5 (3/16) 5.8 (1/4)
±0.2
±0.2 (±0.007)
(±0.007)
(±0.007)
6 (1/4)
7.9 (5/16) 9.5 (5/16)
5 (3/16)
9 (3/8)
9 (3/8)
13 (1/2)
28.5
30 (1-
33 (1-
20 (3/4)
(1-1/8)
3/16)
8.4 (1-
8.4 (1-
8.4 (1-
4.3 (3/16)
3/16)
3/16)
+ 0.2
+0.4
+0.4
(+0.007)
(+0.015)
(+0.015)
(+0.015)
0(0)
0(0)
0(0)
1.15
0.9 (0.03)
(0.04)
(0.05)
Tightening Torque (kgf • cm)
25 (0.03)
8 (3/16)
16
16.5
16
12 (1/2)
(10/16)
(10/16)
±0.2
±0.3 (±0.011)
±0.3 (±0.011)
11.5 (7/16)
+0.3
+0.5 (+0.019)
+0.5 (+0.019)
-0.2
-0.2 (-0.007)
7.7 (5/16)
±0.2
±0.2 (±0.007)
±0.2 (±0.007)
11 (3/8)
15 (5/8)
13 (1/2)
34 (1-3/8)
38 (1-1/2)
5/16)
8.4 (1-3/16)
3/16)
+0.4
+0.4 (+0.015)
+0.4 (+0.015)
0(0)
0(0)
1.45
1.7 (0.06)
12~18
3phase AC power : L1(R), L2(S), L3(T), N
20~30
35 (0.05)
50 (0.07) 70 (0.10)
8 (3/16)
8 (3/16)
8 (3/16)
22 (7/8)
22 (7/8)
24 (1)
±0.3
±0.4
(±0.011)
(±0.011)
17.5
13.3 (1/2)
13.5 (1/2)
(11/16)
+0.5
+0.5
(+0.019)
(+0.019)
-0.2 (-0.007)
-0.2
-0.4
(-0.007)
(-0.015)
11.4
9.4 (3/8)
13.3 (1/2)
(7/16)
+0.3
(+0.011)
±0.4
(±0.015)
-0.2
(-0.007)
17.5
12.5 (1/2)
18.5 (3/4)
(11/16)
13 (1/2)
14 (9/16) 20 (3/4)
43 (1-
50 (2)
51 (2)
11/16)
8.4 (1-
8.4 (1-
8.4 (1-3/16)
3/16)
3/16)
+0.4
+0.4
(+0.015)
(+0.015)
0(0)
0(0)
0(0)
2.0
1.8 (0.07)
1.8 (0.07)
(0.078)
Communication : F1, F2
1phase AC power : L, N
2015-06-25 오후 4:40:23
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae***jxydeh series

Table of Contents