Viking VISC530 Service Manual page 17

Electric induction range
Hide thumbs Also See for VISC530:
Table of Contents

Advertisement

Diagnostics
Built-In Error Codes (cont)
LED
Interface
Failure
Code
Display
6
Error on filter board
EEPROM data wrong
7
Voltage supply
Cable
Filter board
Power board
8
Error code received
which cannot be
assigned
9
Temperature sensor
defective
Mechanical failure
Electrical failure
10
Wrong terminal
connected
Temperature sensor
shows overheat of
induction coil or
power board
Display of the residual
heat
switched OFF).
and off until the zone has cooled.
© 2009 Viking Preferred Service
Possible Reason
Permanent low voltage
Error on electronic device
Lost data or EEPRPM
Missing L2
Loose cable
Defective board
Defective board
Component failure
Communication error
Mechanical crack of sensor
Fading resistance
Power board
Secondary voltage of the
power supply above 400 Volts
Cooking zone overheated
Heat opened thermal
Induction generator
temperature too high
No failure
Temperature over 60˚ C in a
cooking zone
Action
Check voltage–if proper and error
persists replace filter board
Replace filter board
Replace filter board
Verify L2
Repair or replace cable as needed
Replace filter board
Replace power board
Cycle power–if error continues
replace cable–if error continues
replace filter board
Replace power board
Change coil–if issue continues
replace power board
Check the supply power
Allow zone to cool down
Allow to cool down
Error display is canceled after cool-
ing down
Cooking zone needs to cool down
17

Hide quick links:

Advertisement

Table of Contents
loading