5.3 HIGH VOLTAGE
TOP PREVIOUS NEXT
Item/Preparation
1.
Operate the TV set.
2.
Receive the crosshatch pattern.
3.
Set to 0 Beam
(Screen Control : min. CONTRAST : min)
TOP PREVIOUS NEXT
1.
Connect a DC voltage meter to D850 cathode and confirm the voltage is 141.0 ± 2.0V.
2.
Connect a high voltage meter (Electrostatic Type) to an anode of the picture tube.
3.
Confirm that the high voltage is within the range of 31.0 ± 1.0V.
http://servis-manual.com/
Adjustment Procedure