Tools Required: (2) 7/16" socket or box wrenches.
To position the handle at operating height:
Step 1: Remove and keep the hardware securing the
handle to the legs.
Step 2: Raise handle until holes align with the upper
holes in the legs.
Step 3: Re-insert hardware as shown,
securely.
THE PROPER SIZE SO- type feeder cable MUST BE USED for the electrical hook-up of this heater. The proper cable size is shown
in the tables below (A.W.G./ # of conductors.) Table 1 is for cable 50ft. in length or less. Table 2 is for cable longer than 50ft.
A 25ft. cable kit can be purchased from the
factory. Refer to the kit part numbers in table at
right.
CABLE KITS INCLUDE:
25 feet of Type SO cable, with either 3-
conductors or 4-conductors, depending on
the heater requirements.
To order cable kits
Phone: 1-800-495-4525
Feeder cable or cable kit assembly MUST BE made by
licensed electricians ONLY.
Service panel or receptacle used to supply power to
these heaters MUST have a ground bus or ground pole
that is securely bonded to earth ground.
Connect green ground conductor on feeder cable or
cable kit to grounding lug on heaters.
Comply with ALL local electrical codes and the
National Electric Code (NFPA70) when providing
electrical power to these heaters.
Issue Date: 4-19-02 Rev. Date: 11-10-04 Rev. Level: 10
FES – SERIES ASSEMBLY
and fasten

WIRING

Model
Table 1
FES & YES 1520-3A
FES & YES 1524-1A
FES & YES 1524-3E
FES & YES 1548-3E
FES & YES 1560-3A
FES & YES 3048-3A
FES & YES 3060-3A
Model
Table 2
FES & YES 1520-3A
FES & YES 1524-1A
FES & YES 1524-3E
FES & YES 1548-3E
FES & YES 1560-3A
FES & YES 3048-3A
FES & YES 3060-3A
Bolts
Washers
Washers
Unit Rating
Cable Size - Under
15kW, 208 Volt, 3-Ph
15kW, 240 Volt, 1-Ph
15kW, 240 Volt, 3-Ph
15kW, 480 Volt, 3-Ph
15kW, 600 Volt, 3-Ph
30kW, 480 Volt, 3-Ph
30kW, 600 Volt, 3-Ph
Unit Rating
15kW, 208 Volt, 3-Ph
15kW, 240 Volt, 1-Ph
15kW, 240 Volt, 3-Ph
15kW, 480 Volt, 3-Ph
15kW, 600 Volt, 3-Ph
30kW, 480 Volt, 3-Ph
30kW, 600 Volt, 3-Ph
ELECTRICAL SHOCK
FIRE HAZARD
Serious injury or death may
occur.
Disconnect from electrical
supply before installing feeder
cable to these heaters.
Read and follow all safety
information in box to the left.
OIPM P/N 3420458
Nuts
Cable
50ft. long
Kit Number
6/4
03164001
4/3
08805300
6/4
03164001
12/4
03164201
12/4
03164201
6/4
03164001
6/4
03164001
Cable Size – Over
Max. Cable
50ft. long
Length (ft)
4/4
120
2/3
215
6/4
150
12/4
140
12/4
190
6/4
300
6/4
350
HAZARD
Page 4 of 24