Figure 4, Basic Installation - Secura Key Radio Key 600 Operating & Installation Manual

Stand alone proximity access control system
Hide thumbs Also See for Radio Key 600:
Table of Contents

Advertisement

Radio Key
®
2. Pull cable ends through the access hole in the mounting plate:
a. If using the Auxiliary Reader, connect Plug P2 at the cable end to
Socket J2 at the RK600 Unit, grounding the shield at the RK600
Unit end only. The Auxiliary Reader must be connected before
power is applied to the RK600.
b. Connect Plug P1 to Socket J1 on the RK600 Unit circuit board.
3. Attach the housing to the mounting plate:
a. Hold the bottom end of the housing away from the mounting plate.
b. Insert the two tabs (inside top of housing) into the two slots at the
top of the mounting plate.
c. Swing the bottom of the housing toward the mounting plate.
d. Secure by installing the 4-40 x 5/16" Philips screw (supplied) into
the hole at the bottom. The 4-40 x 5/16" Hex Socket tamper-proof
screw (supplied) can be substituted for additional security. The
optional security tool (ST-2) is required in order to use the tamper-
proof screw.
4. Apply power. The LED will flash once and the beeper will sound. Refer
to beginning of this manual for programming and operating instructions.
600
Mounting
Plate
RK600 or Auxiliary
Reader Housing
Figure 4 - Basic Installation
Secura Key  15
Operating & Installation
2-S
Electrical Box