LeeLen JB-304 User Manual

LeeLen JB-304 User Manual

Villa video door entry system
Hide thumbs Also See for JB-304:

Advertisement

J B - 3 0 4
Villa Video Door Entry System
User's Manual
(V3.0)
Please read this manual carefully before the products are installed.Technical specifications
and contents are subject to change accordingly without advance notification.

Advertisement

Table of Contents
loading

Summary of Contents for LeeLen JB-304

  • Page 1 J B - 3 0 4 Villa Video Door Entry System User’s Manual (V3.0) Please read this manual carefully before the products are installed.Technical specifications and contents are subject to change accordingly without advance notification.
  • Page 2: Table Of Contents

    CONTENTS Page Part 1. Product introduction 1.1 Use purpose 1.2 System configuration 1.3 Features and functions Part 2. Technical parameters & structure 2.1 Technical parameters 2.2 Structure 5~11 Part 3. Installation and connection 3.1 Installation 3.2 Connection Part 4. System programming 12~15 4.1 Audio jumper 4.2 Video resistor...
  • Page 3: Part 1. Product Introduction

    Part 1. Product introduction 1.1 Use purpose The system is applied to single family houses, offices, shops, warehouses, and other access control purpose. 1.2 System configuration Configuration Options Remarks ① All panels are aluminum. ② Door stations don't require any direct power supply. ③Card reader is available on Model No.15 and No.18.
  • Page 4: Features And Functions

    1.2.2 Indoor phones Model N60 Model V-26 Model N72B Model F-7 210X150X23(mm) 239X139X20(mm) 180X115X21(mm) 101X135X25(mm) Model N75B 210X150X23(mm) 1.2.3 Power supply Adapter Transformer (DIN Rail) 1.3 Features and functions > Call, answer, and release doors. > DIY system with 4 wires; PLUG & PLAY connection. >...
  • Page 5: Part 2. Technical Parameters & Structure

    Part 2. Technical parameters & structure 2.1 Technical parameters 2.1.1 Door station Camera: 1/3” SONY CCD or 1/3” CMOS Viewing angle: 92° Lens: F=3.6 Resolution: 420TV Line Min. illumination: 0.01 LUX Video output: 1Vp-p/75Ω ≥25dB Audio SNR: ≤7% Audio distortion: ≤60mA Standby current: ≤230mA...
  • Page 6: Power Supply

    2.2.2 Indoor phones A) Model F-7 B) Model V-26 Plastic casing Decorative coat Power indicator Speaker Speaker 4" TFT-LCD Screen Intercom call button Monitor button Answer button Unlock button Answer button Plastic casing Microphone Unlock button Intercom call button Speech volume adjustor Microphone M - + Image adjustors...
  • Page 7: Part 3. Installation And Connection

    Part 3. Installation and connection 3.1 Installation 3.1.1 Door stations Model No. 6 A) Surface mount Big seal a. Take off the coat from the door panel with Small seal expansion plugs the enclosed driver ( ). ① b. Install the expansion plugs in the wall beside the cable( ).
  • Page 8 expansion plugs Model No.15 A) Surface mount a. Take off the door panel from the bracket with the enclosed screw driver( ). ① b. Fix the bracket on the wall with two screws and expansion plugs( ). ② c. Put the door panel on the bracket and fix it ②...
  • Page 9: Connection

    C) Magnetic type a. Fix the bracket on the box or on the wall with the ③ screws( or ). ① ② b. Move the indoor ② phone and put it on ① the bracket after connect the cable( ). ③...
  • Page 10 3.2.2 Terminals Terminals to door station or/and indoor phone. Door station address code wires Both have no difference. Electronic lock selector(jumper) Audio jumper Terminal to power supply Program button Terminal for electronic POWER lock Terminals for gates/garages/lights ... Terminal for electronic SIGNAL lock A) Door stations Lock1 Lock2...
  • Page 11 B. Best connection for up to 4 door stations and 4 indoor phones RVV4x0.5mm e-lock RVV4x0.5mm RVV4x0.5mm e-lock RVV4x0.5mm RVV4x0.5mm e-lock RVV4x0.5mm RVV4x0.5mm e-lock C. Other workable connection C1. Example 1: RVV4x0.5mm RVV4x0.5mm RVV4x0.5mm e-lock e-lock RVV4x0.5mm RVV4x0.5mm RVV4x0.5mm RVV4x0.5mm e-lock e-lock C2.
  • Page 12 ①The basic components are 1 door station, 1 indoor phone, and 1 power supply. The max. capacity t he manufacturer suggests is 4 door stations and 4 indoor phones. More components may cause malfunctions. ②One adapter can support only one video indoor phone while one transformer can support up to 4 indoor phones. But if there are 3 or 4 door stations, one more adapter or transformer is required, because the turning monitor function may be not workable.
  • Page 13 ④ In diagram B, COM terminal has to be connected. NC means close circuit. NO means open circuit. Please choose a right terminal according to the electronic locks. ⑤There is no terminal for power locks on the door station Model No.9. ⑥The electronic locks can keep releasing in 0.5 second only in diagram A, but in 5 seconds in diagram B.
  • Page 14: Part 4. System Programming 12~15

    Part 4. System programming 4.1 Audio jumper The audio jumper has to be put on AF position in the indoor phone if there is only one indoor phone. In case there are more indoor phones, only the last indoor phone is required to do that. Meanwhile the other indoor phones' jumpers have to be put on NC position.
  • Page 15: Card Reader(For Model No.15&No.18 Only)

    4.4 Card reader (for Model No.15 & No.18 only) A. Register master cards The system provides up to 8 master cards. Users may use the card to register or cancel other cards easily. ① a. Push the program button in the back side of the door station with a tool .Release it when the door station sounds a beep.
  • Page 16: Password (For Model No.18 Only)

    4.5 Password settings (for Model No.18 only) Residents are allowed to use passwords to release the doors on the door station Model No.18. There are three group passwords. They are > System password (default:1234). It is the key to change all passwords. >...
  • Page 17 C) Change entry password 2 Step 1> Get into the program status as 4.5.1. Step 2> Push *02*. If it sounds a long beep, then Step 3> Push the new password and end by # button. If it sounds a long beep, then Step 4>...
  • Page 18: Part 5. Operation

    Part 5. Operation 5.1 Operation on door stations 5.1.1 Call residents Push the CALL button on the door station. The door will sound a feedback ring if the calling is successful. The calling can be ended immediately once the call button is pushed again. If there is no answer, the calling will end itself after 15 seconds.
  • Page 19 5.2.3 Release gates/garages ... Push button if the indoor phones are with the function. 5.2.4 Video surveillance Push button and then the image in front of the camera will be displayed on the screen. If there are two or more cameras, surveillance for different entrances is also available by a 2nd, 3rd, or 4th push. During surveillance it is available to speak with somebody outside by pushing button and release the door by pushing button.
  • Page 20 5.2.9 Change the ring tone Keep pushing button for 2 seconds. The indoor phone will ring. Then continue to push the button again and again until the favorite ring sounds. 2" 5.2.10 Adjust the ring & speech volume Turn the wheel to decrease or increase the ring and speech volume. M - + 5.2.11 OSD menu and picture memory 5.2.11.1 Operation on OSD menu...
  • Page 21: Part 5. Operation

    C. Delete the stored images During the reviewing status push button and do not release it for 2 seconds. The dialogue box will display. At this moment push button again, then the viewing page will be deleted. Then push “ ”...
  • Page 22: Part 6. Troubleshooting

    Part 6. Troubleshooting 6.1 Test After all components are installed and connected as the user's manual, please switch the power on and then try to operate all features on all door stations and indoor phones as Part 5. 6.2 Troubleshooting Common malfunctions Possible reasons Obviation...
  • Page 23 No:UG-LLZJ-3046000-E-V3.0...

Table of Contents