Difficulty restarting the engine after use or engine stops suddenly during use.
Possible Fault
No fuel or engine oil
Overheating
Carbon build-up on spark plug
Carburettor blocked
Reduced engine speed/power during use.
Possible Fault
Blocked air filter
Carbon build-up in engine and/or
entry to exhaust silencer
Carbon build-up on spark plug
Carburettor blocked
Generator runs, but connected devices are not receiving power.
Possible Fault
Generator overloaded
Generator runs and AC outputs OK, but no DC output.
Possible Fault
DC output over-current protection
switch tripped
Action
Check fuel level and ensure adequate fuel is available. For some engines, an engine oil
sensor will automatically switch off the engine or prevent starting if a low engine oil level is
detected.
Allow engine to cool before restarting. If possible, improve engine cooling, such as operating
in lower temperatures or in shade etc.
Remove the spark plug and clean any carbon from the electrodes before re-installing it.
Clean the carburettor.
Action
Check and clean air filter.
Remove the engine cylinder head and clean any carbon from the combustion chamber. For
the exhaust silencer, remove it and clean any carbon deposits from the exhaust port.
Remove the spark plug and clean any carbon from the electrodes before re-installing it.
Clean the carburettor.
Action
Check if Overload indicator is illuminated (red). Stop the generator and disconnect all
devices. Start the generator and check that Overload indicator is not lit and that the Power
indicator is illuminated green. Connect a device and check that it is being powered properly,
if not contact an authorized service center.
Action
Reset DC over-current protection switch.