Conversion decoder set

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 28
CV
Explanation
31
PoM
Index high Byte
32
PoM
Index low Byte
Alternative formats:
Bit 0 : Analog AC off = 0 / Analog AC on = 1
50
PoM
Bit 1 : Analog DC off = 0 / Analog DC on = 1
Bit 2 : fx (MM) off = 0 / fx (MM) on = 1
Bit 3 : mfx off = 0 / mfx on = 1
Bit 0: Motor inverted 1= on, 0 off
Bit 1: Light inverted 1= on, 0 off
51
PoM
Bit 2: Track inverted 1= on, 0 off
Bit 3: Aux 3 (1= logical, 0= amplified output)
Bit 4: Aux 4 (1= logical, 0= amplified output)
Motor type ... (Bit 0-4)
... Auxiliary – function outputs 5 and 6
... Motor – Softdrive Sine
... Motor – without feedback control
52
PoM
... Motor – high-efficiency C90
... Motor – bell armature
... Motor – direct current DC soft
... Motor – direct current DC hard
... Motor – direct current DC 1 Gauge
Motor feedback control – feedback control
53
PoM
reference
54
PoM
Motor feedback control – feedback control parameter K
Motor feedback control – feedback control
55
PoM
parameter I
PoM must be supported by the locomotive controller / central controller.
CV Table for DCC
Values
Default
16
16
0
0
0 - 15
0 / 1
0 / 2
15
0 / 4
0 / 8
0 / 1
0 / 2
0
0 / 4
0 / 8
0 / 16
0 - 7
0
1
2
3
5
4
5
6
7
40
0 - 255
0 - 255
80
0 - 255
60
Notes
This is required for advanced settings,
such as CV 300 – 328.
Note:
DCC cannot deactivate itself.
The values of the required settings must
be added up.
Selection of a motor type for additional
settings for motor feedback control
or
Selection of additional function outputs
on an H0 decoder. See extra table for how
motor outputs work as additional auxiliary
functions.
Absolute Vmax for motor characteristic
Feedback control portion K
Feedback control portion I
47