4 Troubleshooting

4 Troubleshooting
PROBLEM
The LED of the CS stays
Amber ON during normal
operation.
The LED of the CS stays
Red ON during normal
operation.
"CLEAR SCAN DATA" is
displayed on the PS's
screen after turning on the
PS.
Cannot register the CS
even when maximum
number of CSs is not
exceeded.
Cannot register the PS.
PS becomes out of range.
Cannot make calls using
the PS.
28
Installation Guide
PROBABLE CAUSE
In LAN synchronization case:
LAN synchronization to
Master CS has failed.
In air synchronization case:
Air synchronization to
Master CS has failed.
CS malfunction
Network failure
The PS cannot be used for
normal operation when
scan data is stored on the
PS.
In air synchronization case:
Air Sync Master is also a
member of Air Sync Group
1, so maximum 15 IP-CSs
are available in this Group.
Wrong Personal
Identification Number (PIN)
is registered to the PS.
Location of CS is not good.
Access system of the PS is
not properly set.
SOLUTION
Check the network configuration (refer
to "5.3 Recommended Network
Configuration").
Diagnose the network configuration
with IP Terminal Maintenance Console
(refer to "5.12 IP Terminal
Maintenance Console").
Check the air synchronization (refer to
"5.6 Air Synchronization").
Replace the CS.
Configure the network settings again
using the IP Terminal Maintenance
Console (refer to "5.12 IP Terminal
Maintenance Console").
Clear the scan data by following the
procedure described in "5.5.5 Clearing
the Stored Scan Data" in this guide.
Change the Air Synchronization Group
No. to None using the Maintenance
Console (refer to PC Programming
Manual for your PBX).
Enter the PIN set to the PBX into the
PS.
Locate the CS properly (refer to
"3.3 Site Survey").
Change the access system setting of
the PS to the appropriate system or
automatic.