Switch S1-1: Local/Remote Configuration; Switches S1-2 And S1-3: Symmetric/Asymmetric Operation; Switch S1-5: General Protection (Signal To Noise Ratio) - Patton electronics COPPER LINK 2174 User Manual

High speed ethernet extender
Hide thumbs Also See for COPPER LINK 2174:
Table of Contents

Advertisement

Switch S1-1: Local/Remote Configuration

Use switch S1-1 to configure the unit as Remote or Local in the Model
2174 pair.

Switches S1-2 and S1-3: Symmetric/Asymmetric Operation

Use switches S1-2 and S1-3 to configure the CopperLink line rate type-
and operation.
S1-2
OFF
OFF
ON
ON
Note
See Appendix D on page 20 for line rate distances.

Switch S1-5: General Protection (Signal to Noise Ratio)

Use switch S1-5 to configure line noise protection.
• 6dB: Original line noise protection with 6dB SNR
• 9dB: Better line noise protection with SNR up to 9dB
Table 2: Local/Remote Unit Configuration
S1-1
ON
CPE/Remote
OFF
CO/Local
Table 3: Symmetric/Asymmetric Selection Chart
S1-3
OFF
High-Speed "Symmetric"
ON
High-Speed "Asymmetric"
OFF
Long-Range "Symmetric"
ON
Long-Range "Asymmetric"
Table 4: Signal to Noise Ratio
S1-5
ON
OFF
Setting
Setting
Setting
6dB
9dB
15