6-
¿©©©©§©©©©©©©©§©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©§©©§©©§©§©¤
FNo.Text
¨©©©©ª©©©©©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©ª©
1701>O/Cpon >Switch on O/C protection phase
1702>O/Cpof >Switch off O/C protection phase
1704>O/Cpbk >Block overcurrent protection phases
1711>O/Ceon >Switch on overcurrent protection earth
1712>O/Ceof >Switch off overcurrent protec. earth
1714>O/Cebk >Block overcurrent protection earth
1721>I>>blk >Overcurrent protection:block stage I>>CG
1722>I> blk >Overcurrent protection:block stage I> CG
1723>Ip blk >Overcurrent protection:block stage Ip CG
1724>IE>>bk >Overcurrent protec.: block stage IE>> CG
1725>IE> bk >Overcurrent protection:block stage IE>CG
1726>IEp bk >Overcurrent protection:block stage IEpCG
1727>C/O
1751O/Cpoff Overcurrent prot. phase is switched offCG
1752O/Cpblk Overcurrent prot. phase is blocked
1753O/Cpact Overcurrent prot. phase is active
1756O/Ceoff O/C protection earth is switched off
1757O/Ceblk O/C protection earth is blocked
1758O/Ceact O/C protection earth is active
1762O/C L1
1763O/C L2
1764O/C L3
1765O/C E
1771FD L1
1772FD L1E
1773FD L2
1774FD L2E
1775FD L12
1776FD L12E O/C fault detection L1-L2-E
1777FD L3
1778FD L3E
1779FD L13
1780FD L13E O/C fault detection L1-L3-E
1781FD L23
1782FD L23E O/C fault detection L2-L3-E
1783FD L123 O/C fault detection L1-L2-L3
1784FDL123E O/C fault detection L1-L2-L3-E
1785FD E
1800FD I>>
1805Trp I>> O/C protection I>> phase trip
1810FD I>
1815Trip I> O/C protection I> phase trip
1820FD Ip
1825Trip Ip O/C protection Ip phase trip
1831FD IE>> O/C fault detection IE>> earth
1833TrpIE>> O/C protection IE>> earth trip
1834FD IE>
1836Trp IE> O/C protection IE> earth trip
1837FD IEp
1839Trp IEp O/C protection IEp earth trip
1850FD dyn
2701>AR on
2702>AR off >AR: Switch off auto-reclose function
2732>AR St. >AR: Start external
2733>ARblSt >AR: External Blocking of Start
2734>ARblCl >AR: External Blocking of reclosure
¥©©©©¦©©©©©©©©¦©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©¦©©¦©©¦©¦©¾
&*&
Meaning
>C/O of overcurrent fault detec. level
O/C fault detection phase L1
O/C fault detection phase L2
O/C fault detection phase L3
O/C fault detection earth
O/C fault detection L1 only
O/C fault detection L1-E
O/C fault detection L2 only
O/C fault detection L2-E
O/C fault detection L1-L2
O/C fault detection L3 only
O/C fault detection L3-E
O/C fault detection L1-L3
O/C fault detection L2-L3
O/C fault detection E only
O/C fault detection stage I>>
O/C fault detection stage I>
O/C fault detection Ip
O/C fault detection IE> earth
O/C fault detection IEp earth
O/C prot. : dynamic parameters active
>AR: Switch on auto-reclose function
$SSHQGL[
OpFtIO
IO
IO
IO
IO
IO
IO
IO
IO
IO
IO
IO
IO
IO
O
CG
O
CG
O
CG
O
CG
O
CG
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CG O
C O
CG O
C O
CG O
C O
CG O
C O
CG O
C O
CG O
C O
CG
O
IO
IO
CGCGIO
CGCGIO
CGCGIO