DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the appliance, first remove the exhaust filter cover
and filter.
- Remove the hinge lock-pin (see pictures).
- Remove the dustcover by simultaneously pushing the click
hook in the hinge and bending the hinge outside with a
screwdriver (see picture).
- To be able to remove the upper housing the cord outlet
must be removed using a screwdriver in the lower section
(see picture).
2
- After removing the 6 screws (A) the upper housing can be
removed.
- When the repair is finished, check whether all functions of
the appliance work properly.
- To disassemble the cord winder, use TORX screwdriver
no. T10, which is one of a set consisting of T20; T15; T10;
T9; T8; T7 and T6 (code number 4822 395 50145).
REPAIR INSTRUCTION
- The spare parts have been standardized as much as possible.
- Depending on the original cord, the spare cord must be
shortened to the length of the original cord.
- The cord winder spring must be tensioned to the maximum
level and then be rewound approx. 1.5 turn.
- Item 16, safety valve, opens to cool the motor if the air
displacement is too low or if the airflow is blocked.
ELECTRICAL DIAGRAM
MOTOR
POWER
MODULE
Black
Black
Brown
White
FC9080
1
M
CORD WINDER
2-7

Advertisement