WIRING DIAGRAM

7
PUZ-A18NHA6
PUZ-A18NHA6-BS
[LEGEND]
SYMBOL
NAME
TB1
Terminal Block<Power Supply, Indoor/Outdoor>
MC
Motor for Compressor
MF1
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
63H
High Pressure Switch
TH3
Thermistor<Liquid>
TH6
Thermistor<2-Phase Pipe>
TH7
Thermistor<Ambient>
TH8
Thermistor<Heat Sink>
TH32
Thermistor<Comp. Surface>
TH33
Thermistor<Suction>
LEV-A
Linear Expansion Valve
ACL
Reactor
CY1,CY2
Capacitor
P.B.
Power Circuit Board
TABR/S
Connection Terminal<L1/L2-Phase>
TABU/V/W
Connection Terminal<U/V/W-Phase>
C. B.
TH33
TH32
MF1
MS
3~
CNF1
1
(WHT)
7
1
3
1
TH33
TH32
(YLW)
(BLK)
3
TRANS
1
CNDC
(PNK)
F2
CNAC
CNS
(WHT)
(WHT)
1
F1
3
1
3
P. B.
PFC
TABR
RED
WHT
TABS
CB1
1 MODEL SELECT
is the switch position
MODEL
SW6
SW5-5.6
ON
ON
PUZ-A18NHA6
OFF
OFF
1 2 3 4 5 6
7 8
1 2 3 4 5 6
ON
ON
PUY-A12NHA6
OFF
OFF
1 2 3 4 5 6
7 8
1 2 3 4 5 6
ON
ON
PUY-A18NHA6
OFF
OFF
1 2 3 4 5 6
7 8
1 2 3 4 5 6
2. SW5-1 to 4 : Function switch
OCH577A
SYMBOL
PFC
Converter
IPM
Power Module
CB1,CB2,CB3
Main Smoothing Capacitor
N.F.
Noise Filter Circuit Board
LI/LO
Connection Terminal<L1-Phase>
NI/NO
Connection Terminal<L2-Phase>
EI,E2,E3
Connection Terminal<Ground>
52C
52C Relay
C.B.
Controller Circuit Board
SW1
Switch<Manual Defrost, Defect History,
Record Reset, Refrigerant Address>
SW4
Switch<Test Operation>
SW5
Switch<Model Select, Function Switch>
SW6
Switch<Model Select>
SW7
Switch<Function Switch>
SW8
Switch<Function Switch>
SW9
Switch<Function Switch>
LEV-A
63H
M
TH7 TH6 TH3
1
6
2
1
4
1
2
1
TH7/6
TH3
LEV-A
CNVMNT
(RED)
(WHT)
(WHT)
(WHT)
1
1
3
(WHT)
63H
(YLW)
CN2
CN4
(WHT)
(WHT)
1
7
1 2
2
5
F3
2
3
1
21S4
3
1
F4
(GRN)
(BLU)
4
21S4
PUZ only
RED
RED
WHT
WHT
ACL
MC
MS
3~
W
U
V
2
CN5
1
(RED)
2
IPM
2
CN4
1
(WHT)
2
TABU
CN3
1
TABV
(WHT)
2
TABW
TH8
5
1
CN2
(WHT)
CB2
CB3
7
L1
L2 GR S1 S2 S3
POWER SUPPLY
208 / 230V 60Hz
Use copper supply wires.
Utilisez des fils d'alimentation en cuivre.
PUY-A12/18NHA6
NAME
SYMBOL
LED1,LED2 LED<Operation Inspection Indicators>
F1,F2,F3,F4
SWP
CN31
SS
CNM
CNMNT
CNVMNT
CNDM
CN51
X51,X52,X55 Relay
When M-NET adapter is connected
5
3
5
3
1
5
CNMNT
2
(WHT)
1
14
CNM
CN31
CN52C
(RED)
1
2
3
A B S
1
2
5
1
SS
SV2
3
1
(WHT)
RED
WHT
N. F.
LO
NO
1
3
1
3
LI
EI
NI
CY1
CY2
TB1
INDOOR
UNIT
16
PUY-A12/18NHA6-BS
NAME
Fuse<T6.3AL250V>
Switch<Pump Down>
Connector<Emergency Operation>
Connector<Connection for Option>
Connector<Connection for Option>
Connector
<Connected to Optional M-NET Adapter Board>
Connector
<Connected to Optional M-NET Adapter Board>
Connector<Connection for Option>
Connector<Connection for Option>
5
CN5
(WHT)
1
M-NET ADAPTER
CN2M
CND
(WHT)
(WHT)
3
1
3
TB7
M-NET
M-NET ADAPTER
SYMBOL
NAME
TB7
Terminal Block <M-NET connection>
1
2
CN5
Connector <Transmission>
2
CND
Connector <Power Supply>
CN2M
Connector <M-NET communication>
1
2
2