Led Inspection - Yamaha STAGEPAS 600i Service Manual

Hide thumbs Also See for STAGEPAS 600i:
Table of Contents

Advertisement

● V-BUS port
The result is displayed in output window as shown below.
When Normal
PASS: V-SUB *(x.xx V)
2.50 V ~ 2.70 V
When Abnormal
2.49 V or below
FAIL: V-SUB *(x.xx V)
2.71 V or above
FAIL: V-SUB *(x.xx V)
*(x.xxV) represents electric pressure measured.

3-4. LED inspection

LIMIT LED lights.
Conduct inspection whether it turns
off the light.
SIGNAL LED lights.
turns off the light.
POWER LED lights.
turns off the light.
REVERB-ON LED lights. → Conduct inspection whether
it turns off the light.
FBS LED lights. → Conduct inspection whether it turns off
the light.
BOOST LED lights. → Conduct inspection whether it
turns off the light.
Conduct inspection whether all LEDs light or not.
* FBS = FEEDBACK-SUPRESSOR
Click "OK" button and each LED test is started.
In consideration of a case that operator misses a sequence
of action that turns on
reconfi rm the successive test with "Retry" button.
Conduct inspection whether it
Conduct inspection whether it
off the LED, it's possible to
● V-BUS port
検査結果はアウトプットウインドウへ下記のように
表示されます。
正常時
2.50 V ∼ 2.70 V PASS: V-SUB *(x.xx V)
異常時
2.49 V 以下
FAIL: V-SUB *(x.xx V)
2.71 V 以上
FAIL: V-SUB *(x.xx V)
*(x.xxV) は、測定した電圧を表示します。
3-4. LED 検査
LIMIT LED が点灯→消灯するか検査を行います。
SIGNAL LED が点灯→消灯するか検査を行います。
POWER LED が点灯→消灯するか検査を行います。
REVERB-ON LED が点灯→消灯するか検査を行い
ます。
FBS LED が点灯→消灯するか検査を行います。
BOOST LED が点灯→消灯するか検査を行います。
全 LED が点灯するか検査を行います。
「OK」ボタンをクリックして、各 LED テストを開
始します。
オペレータが LED の点灯→消灯を見逃すケースを
考慮し、 「Retry」ボタンでの一連のテストの再確認
が可能です。