To Clean
Out the Salt
Storage Tank
27
A periodic clean-out of the Salt Storage Tank is necessary to keep your Culligan Water Conditioner at
peak operating efficiency. Do it at least every 2 years when the salt supply is low. Follow these step-
by-step procedures:
Tools needed:
Scoop
Clean, bucket-size container
Phillips-head screwdriver
Garden hose, Household scrub brush or sponge
1.
Remove the salt storage tank cover and the cap from the brine valve chamber.
2.
Lift the brine valve out of the brine valve chamber and set aside in an upright position.
3.
If you'd like to save any clean, dry salt remaining in the tank, remove it and place it in a clean
container.
4.
Using the scoop, dig out and discard as much remaining salt, water and debris as possible.
5.
Remove the brine valve chamber by removing the chamber retaining screw and nut.
6.
Remove the salt plate at the bottom of the tank.
7.
Lay the salt tank on its side and direct a brisk stream of water from your garden hose to its inside
to rinse out all residue.
8.
Using a household scrub brush and a mild soapy solution, clean the salt plate. This will complete
the tank cleaning.
9.
Stand salt tank upright. Make sure to place the tank on a flat, smooth, solid surface.
10. Replace the salt plate. Place brine valve chamber in position and affix with screw and nut.
11. Insert the brine valve into the chamber and replace brine valve chamber cap.
12. Fill the salt storage tank with 4 to 6 inches of water.
13. Fill the tank with salt to within a few inches of the top.
14. Replace salt storage tank cover.
Troubleshooting
The Culligan Medallist Series Softener is equipped with an advanced error detection system. During
all operating modes the softener's electronics are performing self-diagnostics to ensure that the unit is
operating correctly. There may be times, however, when something may occur that could cause the
unit to improperly operate. In those instances the microprocessor will identify the exact problem and
alert the user with a telephone handset symbol in the upper left corner of the display and the error
code will be shown. Shown below is codes that would appear if an error is detected.
Display
E1
E2
E3
If an error code appears that requires an authorized service technician please contact your local
Culligan Dealer.
For any additional troubleshooting or service needs please contact your local Culligan Dealer.
Error Description
Motor will not stop turning
Motor stuck
Wrong position
Response
Call Culligan service technician
Call Culligan service technician
Call Culligan service technician