Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in
RackSwitch G8264CS solutions.
Table 14. Power distribution units
Description
0U Basic PDUs
0U 24 C13 16A 3 Phase PDU with IEC 309 P+N+Gnd line cord
0U 24 C13 30A 3 Phase PDU with NEMA L21-30P line cord
0U 24 C13 30A PDU with NEMA L6-30P line cord
0U 24 C13 32A PDU with IEC 309 P+N+Gnd line cord
0U 12 C19/12 C13 32A 3 Phase PDU with IEC 309 3P+N+Gnd line cord
0U 12 C19/12 C13 60A 3 Phase PDU with CS8365L 3P+Gnd line cord
Switched and Monitored PDUs
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord
1U 12 C13 Switched and Monitored DPI PDU (without line cord)
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
0U 24 C13 Switched and Monitored 30A PDU with NEMA L6-30P line cord
0U 24 C13 Switched and Monitored 32A PDU with IEC 309 P+N+Gnd line cord
0U 12 C19/12 C13 Switched and Monitored 32A 3Ph PDU with IEC 309 3P+N+G cord
0U 12 C19/12 C13 Switched and Monitored 50A 3Ph PDU with CS8365L 3P+Gnd cord
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord)
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
DPI C13 Enterprise PDU+ (without line cord)
DPI Single Phase C13 Enterprise PDU (without line cord)
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord)
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
Universal PDUs (7x IEC 320 C13 outlets)
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord)
DPI Universal Rack PDU with US LV and HV line cords
DPI Universal Rack PDU with CEE7-VII Europe line cord
DPI Universal Rack PDU with Denmark line cord
Lenovo RackSwitch G8264CS
Part number
46M4122
46M4125
46M4128
46M4131
46M4143
46M4140
46M4002
46M4003
46M4004
46M4005
46M4116
46M4119
46M4137
46M4134
71762NX
71763NU
39M2816
39Y8941
39Y8948
39Y8923
39Y8938
39Y8939
39Y8934
39Y8940
39Y8935
00YE443
39Y8951
39Y8952
39Y8953