Standalone termination unit with g.703 interface
Hide thumbs Also See for M/HDSL Standalone Termination Unit Hotwiret 7986:
Table of Contents

Advertisement

Table 7. General SNMP Management Options
SNMP Management
Possible Settings: Enable, Disable
Default Setting: Disable
Enable or disables the SNMP management features.
Community Name 1
Possible Settings: ASCII text field, Public
Default Text: Public
Identifies the name of the community allowed to access the unit's MIB. The community
name must be supplied by an external SNMP manager when that manager attempts to
access an object in the MIB.
Name 1 Access
Possible Settings: Read, Read/Write
Default Setting: Read
Determines the access level for Community Name 1.
Community Name 2
Possible Settings: ASCII text field, Public
Default Text: Public
Identifies the name of the second community allowed to access the unit's MIB. The
community name must be supplied by an external SNMP manager when that manager
attempts to access an object in the MIB.
Name 2 Access
Possible Settings: Read, Read/Write
Default Setting: Read
Determines the access level for Community Name 2.