4. Color
1) VCR ÒPBÓ, Color bar standard tape.
2) TP-B and EVR.
3) Connect the probe of oscilloscope to TP-B.
4) By using ÒMENUÓ button of unit, change the
adjustment address to 04 COLOR EPR:XX
EVR:XX.
5) By using the ÒDISPLAY/C.RESETÓ button of unit,
adjust the yellow level is same as pedestal level.
6) Confirm with ÒTITLEÓ button of unit.
6. TINT (SCL100/SCL150 only)
1) VCR ÒPBÓ, Color bar standard tape.
2) TP-B and EVR.
3) Connect the probe of oscilloscope to TP-B.
4) By using ÒMENUÓ button of unit, change the
adjustment address to 03 TINT EPR:XX
EVR:XX.
5) By using the ÒDISPLAY/C.RESETÓ button of unit,
adjust so that the red level is same as green level.
6) Confirm with ÒTITLEÓ button of unit.
GREEN LEVEL
Samsung Electronics
RED LEVEL
5. C COM (VP-L100/VP-L150 only)
1) VCR ÒPBÓ, Color bar standard tape.
2) TP-B and LL205.
3) Connect the probe of oscilloscope to TP-B.
4) By using ÒMENUÓ button of unit, change the
adjustment address to 04 COLOR EPR:XX
EVR:XX.
5) By using the ÒLL205Ó of LCD PCB,
adjust the red level carrier is minimized.
6) Confirm with ÒTITLEÓ button of unit.
LCD PCB (COMPONENT SIDE)
Alignment and adjustment
RED LEVEL CARRIER
5-35