Dual 1x4 3-gb/s/hd/sd distribution amplifiers with reclocking / dual 1x4; sd-sdi distribution amplifiers with reclocking/ dual 1x4 sd-sdi distribution; amplifiers/ single 1x8 3gb/s/hd/ sd distribution amplifiers with reclocking / single 1x8 3gb /s/hd/sd d
1x8 looping input sd/asi distribution
amplifiers / 1x8 looping input sd/asi
distribution amplifiers with reclocking /
1x8 looping input 3 gb/s, hd-sdi, sd-sdi,
and asi distribution amplifiers / 1x8 looping input 3 gb/s, hd-sdi, sd-sdi, and asi
di (32 pages)
Three-channel serial monitoring distribution amplifier (52 pages)
Summary of Contents for Imagine DA-DHR6802+
Page 1
Installation and Operation Manual DA-DHR6802+/ DA-DSR6802+:/ DA-DH6802+/ DA-DS6802+/ DA-HR6802+/ DA-H6802+ Dual 1×4 3-Gb/s/HD / SD Distribution Amplifiers with Reclocking/ Dual 1×4 SD-SDI Distribution Amplifiers with Reclocking/ Dual 1×4 SD-SDI Distribution Amplifiers/ Single 1×8 3-Gb/s/HD / SD Distribu- tion Amplifiers with Reclocking/ Single 1×8 3-Gb/ s/HD / SD Distribution Amplifiers Edition D 175-000386-00...
This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. 6800+ DA-DHR6802+: Dual 1×4 3 Gb/s / HD / SD Distribution Amplifiers with Reclocking DA-DH6802+: Dual 1×4 3 Gb/s/HD / SD Distribution Amplifiers DA-DSR6802+: Dual 1×4 SD-SDI Distribution Amplifiers with Reclocking DA-DS6802+: Dual 1×4 SD-SDI Distribution Amplifiers DA-HR6802+: Single 1×8 3 Gb/s / HD / SD...
Contents Preface Manual Information ................vii Purpose ................... vii Audience ..................vii Revision History ................viii Writing Conventions ............... ix Obtaining Documents ..............ix Unpacking/Shipping Information ............x Unpacking a Product .................x Product Servicing ................x Returning a Product ................x Safety Standards and Compliances ............xi Safety Terms and Symbols .............
Page 6
Contents Chapter 2: Installation Overview ....................9 Maximum 6800+ Frame Power Ratings ..........10 Unpacking the Module ................11 Preparing for Installation ............... 11 Checking the Packing List ............. 12 Setting Jumpers ..................14 Setting J1/J2 Jumpers ..............14 Setting J3 Jumpers ................. 15 Setting J4/J5 Jumpers ..............
Page 7
Contents Chapter 4: Specifications Overview ....................31 Inputs ......................32 Outputs ....................33 Performance ...................34 Power Consumption................34 Temperature ...................34 Start-Up Time ..................34 Index Keywords ....................35 DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual...
Page 8
Contents DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual...
Preface Manual Information Purpose This manual details the features, installation procedures, operational procedures, and specifications of the following distribution amplifiers: • DA-DHR6802+ dual 1×4 3-Gb/s / HD / SD distribution amplifiers with reclocking • DA-DH6802+ dual 1×4 3-Gb/s / HD / SD distribution amplifiers •...
Preface Revision History Table P-1. Manual Revision History Edition Date Revision History May 2007 Initial release August 2007 Added information about single channel distribution amplifiers October 2007 Removed information about single channel SD-SDI distribution amplifiers March 2008 Corrected 3.0 Gb/s cable equalization specification viii DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual...
Preface Writing Conventions To enhance your understanding, the authors of this manual have adhered to the following text conventions: Table P-2. Manual Style and Writing Conventions Term or Description Convention Bold Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names.
Preface Unpacking/Shipping Information Unpacking a Product This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble free service. 1. Check equipment for any visible damage that may have occurred during transit. 2. Confirm that you have received all items listed on the packing list. 3.
Preface Safety Standards and Compliances See the 6800+ Safety Instructions and Standards Manual to find the safety standards and compliances for this 6800+ series product. A safety manual is shipped with every FR6802+ Frame Installation and Operation Manual and can be downloaded from our website. Alternatively, contact your Customer Service representative for a copy of this safety manual.
Preface Restriction on Hazardous Substances (RoHS) Directive Directive 2002 / 95 / EC—commonly known as the European Union (EU) Restriction on Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling.
Preface Waste from Electrical and Electronic Equipment (WEEE) Directive The European Union (EU) Directive 2002 / 96 / EC on Waste from Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products.
Page 16
Preface DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1 Introduction Overview The following topics are described in this chapter: • “Main Features” on page 2 • “Module Descriptions” on page 5 • “Product Description” on page 2 •...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Product Description The DA-DHR/DH/DSR/DS/HR/H6802+ series of distribution amplifiers are designed to distribute serial digital video signals according to SMPTE 257C, 292M, 424M, DVB, and other related standards. They feature high reliability, excellent video performance, and low cost.
Page 19
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction • Re-lockable for DVB-ASI signal • Reclock status and rate report by LEDs • Reclocking Bypass mode is selectable as automatic or enforced • Card-edge control by jumpers with LED display •...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction • Enable automatic switching input between input 1 and input 2 in the 1×8 configuration when a loss of the input signal is detected • Input signal presence detect and report •...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Module Descriptions Front Module Figure 1-1 is a generic top-front view of a typical front module. See Figure 3-1 on page 20 for jumper locations; see Figure 3-2 on page 28 Figure 3-3 on page 29 for LED locations.
Page 22
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction SDI OUT 1 SDI OUT 2 Figure 1-2. Back Module for FR6802+XF or FR6802+QXF Frame DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Signal Flow 3 Gb/s/HD/SD-SDI out 1-1 3 Gb/s/HD/SD-SDI Invert out 1-2 3 Gb/s/HD/ Equalizer Reclocker SD-SDI in 1 3 Gb/s/HD/SD-SDI out 1-3 3 Gb/s/HD/SD-SDI Invert out 1-4 4×4 matrix 3 Gb/s/HD/SD-SDI...
Page 24
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2 Installation Overview This chapter describes DA-DHR/DH/DSR/DS/HR/H6802+ modules’ installation process, including the following topics: • “Installing and Removing Modules” on page 18 • “Maximum 6800+ Frame Power Ratings” on page 10 •...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation Maximum 6800+ Frame Power Ratings Power consumption information is listed in Chapter 4: “Specifications” on page Table 2-1 describes the maximum allowable power ratings for 6800+ frames. Note the given maximums before installing any 6800+ modules in your frame.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation Unpacking the Module Preparing for Installation Before you install DA-DHR/DH/DSR/DS/HR/H6802+ modules, perform the following: • Check the equipment for any visible damage that may have occurred during transit. •...
DA-DHR6802+ Distribution Amplifier Modules with Reclocking • One DA-DHR6802+ front module DA-DHR6802+ • One DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual • One DA-DHR6802+ front module DA-DHR6802+D • One standard double-slot back connector • One DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual • One standard double-slot back connector DA-DHR6802+DR DA-DH6802+ Distribution Amplifier Modules •...
Page 29
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation Table 2-3. Single 1×8 Distribution Amplifier Modules Packing List Ordered Product Content Description DA-HR6802+ Distribution Amplifier Modules with Reclocking • One DA-HR6802+ front module DA-HR6802+ • One DA-DHR/DH/DSR/DS/HR/H6802+ Installation and Operation Manual •...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation Setting Jumpers You need to configure modules for local or remote operation before power-up. To change the configuration, first remove power from the module, reset the jumper, and then reapply power. Setting J1/J2 Jumpers The J1 and J2 jumpers are used to select local control reclock setting.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation Setting J3 Jumpers The J3 jumper is used to set channel configuration, control mode, and enabling input backup. Follow this procedure to set the jumper: 1. Locate jumper set J3 on the module. Figure 2-2 shows the standard location of the jumper set.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation Setting J4/J5 Jumpers The J4 and J5 jumpers are used to set the output slew rate control. Follow this procedure to set the jumpers: 1. Locate the J3 and J4 jumper sets on the module. Figure 2-3 shows the standard location of the jumper sets.
Page 33
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation 2. Place a jumper on the pins that correspond to the slew rate you want. See Table 2-4. Table 2-4. J4/J5 Jumper Set Settings Slew Rate Settings Modules Using This Setting Automatic Reclockable input signal in...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 2: Installation Installing 6800+ Modules Required Frames and Back Module Connector Types These modules have double-width back connectors that can be installed in an FR6802+XF or FR6802+QXF frame. See the FR6802+ Frame Installation and Operation Manual for details on installing back connectors in an FR6802+ frame.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3 Operation Overview This chapter describes how to operate DA-DHR/DH/DSR/DS/HR/ H6802+ modules using local controls only. See the following documents for information on how to operate this product remotely: + Pilot Lite™...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation Operating Notes When you change a control parameter on a DA-DHR/DH/DSR/DS/HR/ H6802+ module, the effect is immediate. However, the module requires up to 20 seconds to save the latest change. After 20 seconds, the new settings are saved and will be restored if the module loses power and must be restarted.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation J1/J2 Jumpers You can use the J1 (for channel 1 control) or J2 (for channel 2 control) jumper to select local control reclock setting. Figure 3-1 on page 20 illustrates the location of these jumpers.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation • Manual-high slew rate: for DA-DH6802+ and DA-H6802+; or for non-reclockable input signal in DA-DHR6802+ and DA-HR6802+ modules • Manual-low slew rate: for DA-DH6802+ and DA-H6802+; or for non-reclockable input signal in DA-DHR6802+ and DA-HR6802+ modules J4/J5 jumper settings are not required for DA-DSR6802+ and...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation Setting Locally Controlled Parameters Local Control Reclocking Mode In the local control reclock setting operation mode, all of the settings’ data status information appears on the + Pilot Lite control screen; however, you cannot change any setting in this mode via + Pilot Lite.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation Setting Remotely Controlled Parameters Table 3-2 Table 3-3 on page 25 describe parameters that are accessible remotely. See your CCS control software application manual or online help for more information on setting and monitoring these parameters remotely.
Page 41
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation Table 3-3. DA-DHR6802+, DA-DSR6802+, DA-HR6802+ Remotely Controlled Parameters Name Range Description • Disable Backup Mode Loss of signal (input 1) switching enable, • Enable automatically switch both output MUXs to select input 2 when input 1 has lost its input signal •...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation Changing Parameter Settings You can change module parameter settings locally with the card-edge jumper or remotely by selecting the Reclocking Mode parameter setting. Changing Parameters Using CCS Software Before using CCS software applications to change your module’s parameter settings, you must refresh (+ Pilot Lite) or discover (Pilot and Navigator) the module.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation You can now switch to Control mode by selecting Operational Mode > Control from the main menu. Double-click DA-DHR/DH6802+ or DA-DSR/DS6802+, as appropriate, in the Navigation pane. The Control window opens, displaying the module’s controls.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation LEDs and Alarms Module Status Indicator LED Figure 3-2. Module Status Indicator LED A module status LED reports the state of the module. See Figure 3-1 on page 20 for the location of this LED, and Table 3-4...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation Module-Specific LEDs Figure 3-3. Module-Specific LEDs Each 6800+ module has a number of LEDs assigned to indicate varying states / functions. These functions are listed in Table 3-5.
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Operation Alarms If an alarm is triggered within your DA-DHR/DH/DSR/DS/HR/ H6802+ module, the Status LED will turn off. Alarms are usually logged and monitored within the available 6800+ software control applications (for example, + Pilot Lite or Pilot).
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 4 Specifications Overview The following specification tables appear in this chapter: • “Inputs” on page 32 • “Outputs” on page 33 • “Power Consumption” on page 34 • “Performance” on page 34 •...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 4: Specifications Inputs Table 4-1. Input Specifications Item Specification Number of inputs Dual channel mode 1 each channel Single channel mode Signal type 3G, HD, SD, ASI Connector BNC per IEC169-8 Impedance 75Ω...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 4: Specifications Outputs Table 4-2. Output Specifications Item Specification Number of outputs Dual channel mode 4 each channel Single channel mode Signal type 3G, HD, SD, ASI Connector BNC per IEC169-8 Impedance 75Ω...
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 4: Specifications Performance Table 4-3. Performance Specifications Item Specification Jitter 0.2 UI for reclocking DA 0.3 UI for non-reclocking DA (reference only) Propagation ~ 4.0 ns (for reference only) Power Consumption Module power consumption is <...
Index Keywords remote parameters 24 setting jumpers 14–17, 20–22 Adjustable parameters 22 signal flow 7 Alarms 30 specifications Applications 4 input specifications 32 output specifications 33 performance specifications 34 Back connectors. See Back modules power consumption 34 Back modules 5–6, start-up time 34 Backup_EN switch 21 temperature specifications 34...
Page 52
Index DA-DS6802+ features 4 alarms 30 front module 5 applications 4 product 2 description LEDs 28–29 back module 5–6 packing list 13 features 3 reclock modes 14 front module 5 remote parameters 24 product 2 setting jumpers 14–17, 20–21 LEDs 29 signal flow 7 packing list 12 specifications...
Page 53
Index LEDs 28–29 local control 23 module descriptions remote control 21 back modules 5–6 understanding jumper controls 20–23 front modules 5 14, 21, product description 2 14, 21, Directives Restriction on Hazardous Substances xii 16–17, 21–22 Waste from Electrical and Electronic Equipment 16–17, 21–22 xiii...
Page 54
Index channel configuration switch 21 Reclock modes jumper control types 20 Remote control jumpers 21 LEDs 28–29 Remotely controlled parameter list 24–25 local jumper controls 23 Removing modules 18 operating notes 20 Restriction on Hazardous Substances (RoHS) parameters directive xii changing settings 26 lists 23–25 parameter types 22...
Need help?
Do you have a question about the DA-DHR6802+ and is the answer not in the manual?
Questions and answers