Protection against abnormality

When the temperature detected by the thermostats /3 (TS3) [1] gets to 180 ± 7°C, the AC power line to the fus-
ing heater lamp/1 (L2) and /2 (L3) is cut off to turn off L2 and L3. When the temperature to detect the thermostat
/4 (TS4) [2] reaches 110 ±10°C, the AC power line to the fusing heater lamp/3 (L4) is cut off to turn L4 OFF. The
thermistors /1 (TH1) [4] and /2 (TH2) [3] detect the temperature of the fusing roller/Up at the center and on both
ends at a specified interval. When an abnormal temperature is detected, the power supply to L2, L3 and L4 is
turned off with a trouble cord displayed on the operation panel. For details of the abnormality detected, see the
trouble codes.