OPTIONAL CONNECTIONS, CONFIGURATION, AND BATTERY SELECTION
A number of optional connections are possible. Undo the four screws at the front of the enclosure and remove
the front panel.
NOTE: ALL 230v & 12V POWER must be fully isolated and turned off prior to removing the cover of this unit.
ONLY TECHNICALLY COMPETENT AND TRAINED technicians should alter and install any additional products
features to the unit.
TEMPERATURE SENSOR
The temperature sensor supplied with the product may be used for temperature-compensated charging. The
sensor is insulated and must be mounted on the batteries negative terminal. Default output voltages for Float
and Absorption are at 25°C. In adjust mode temperature compensation is disabled.
VICTRON BMV600S BATTERY MONITOR
The BMV600S provides real time information for the battery or bank of multiple batteries:
Battery voltage
Discharge current
Capacity as a %
Please refer to product installation manual.
VICTRON BLUE POWER PANEL
The Blue Power Panel provides control and monitoring of the Victron Inverter/Charger. Features include on/off
control of MultiPlus Inverter/Charger units and graphic illustration of system charge/discharge, capacity in %
real time and time to go until discharged. Please refer to product installation manual.
VICTRON COLOR CONTROL PANEL
The Color Control Panel adds a number of extra features over the Blue Power Panel such as Ethernet or Sim
Card internet capability with remote monitoring via web portal and data storage on SD card. Please refer to
product installation manual.

CONFIGURATION

Settings should be carried out by a competent person.
Carefully read the instructions before changes are made.
Batteries should be placed in a dry and well-ventilated area during charging and not directly below the
MultiPlus.
Standard settings: ready for use
On delivery, the MultiPlus is set to standard factory values ready for use as part of a Newton Pumping System
with charging voltages set for the three batteries supplied by Newton Waterproofing Systems for use within
power supplies of 230V input voltage and 50Hz frequency. Inverter output voltage is set to 230V AC. There is no
need to change any of the default settings for use within the UK.

BATTERY SELECTION

The following batteries have been selected to be used with the MultiPlus Inverter/Charger units:
NorthStar 60FT - 60Ah, 99.9% lead, extra long life battery - 12V - Purchase code BB20
NorthStar 100FT - 100Ah, 99.9% lead, extra long life battery - 12V - Purchase code BB21
NorthStar 190FT - 190Ah, 99.9% lead, extra long life battery - 12V - Purchase code BB22
Multiple batteries can be used in parallel to increase the charge of the 12V supply to the inverter. Please refer to
the data sheet for further information. The maximum sized battery bank that can be used with each MultiPlus
12/3000/120 is 1200Ah