LRV Correct
Do LRV
(DE only)
Correct
<Return>
URV Correct
Do URV
(DE only)
Correct
Revision 3
Executing this selection corrects the Input 1
Calibration Low Point based on the input
measurement.
The current live value of the Input 1 Sensor is
shown on this display so the user can easily
see the effect of the correction.
Executing this selection corrects the Input 1
Calibration High Point based on the input
measurement.
The current live value of the Input 1 Sensor is
shown on this display so the user can easily
see the effect of the correction.
Executing this selection corrects the Input 2
Calibration Low Point based on the input
measurement.
The current live value of the Input 2 sensor is
shown on this display so the user can easily
see the effect of the correction.
Executing this selection corrects the Input 2
Calibration High Point based on the input
measurement.
The current live value of the Input 2 sensor is
shown on this display so the user can easily
see the effect of the correction.
Executing this selection resets the Sensor 1 and
calibrations back to Factory values.
Executing this selection resets the Sensor 2
calibrations back to Factory values.
Executing this selection corrects the LRV based
on the input pressure.
The current live value of the primary pressure
input is shown on this display so the user can
easily see the effect of the LRV correction.
Executing this selection corrects the URV based
on the input pressure.
The current live value of the primary pressure
input is shown on this display so the user can
easily see the effect of the URV correction.
STT850 Temperature Transmitter User's Manual
Press  to enter
menu selection
Scroll to Do Cal
Press  to initiate
Press  to enter
menu selection
Scroll to Do Cal
Press  to initiate
Press  to enter
menu selection
Scroll to Do Cal
Press  to initiate
Press  to enter
menu selection
Scroll to Do Cal
Press  to initiate
Press  to enter
menu selection
Scroll to Reset
Cals
Press  to initiate
Press  to enter
menu selection
Scroll to Reset
Corrects
Press  to initiate
Press  to enter
menu selection
Scroll to Do LRV
Correct
Press  to initiate
Press  to enter
menu selection
Scroll to Do URV
Correct
Press  to initiate
Page 29