Fire pumps, water transfer pumps, ultralites trash pumps, poly chemical pumps (24 pages)
Summary of Contents for BE SP-550SD
Page 1
Model # SP-550SD SP-900SD SP-750TD ST-900SD Grounding The grounding conductor of the power cord and switch are terminated in listed double crimpled closed loop connectors that are secured to the motor enclosure by a screw that engages at least two threads into metal and star washer or lockwasher.
Page 2
Using the Operator’s manual The operating manual is an important part of your Submersible Pump and should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being addressed. Reading the owner’s manual thoroughly will help avoid any personal injury or damage to your pump.
product identification Record Identification Numbers Submersible Pump If you need to contact an Authorized Dealer or Customer Service line (1-866-850-6662) for information on servicing, always provide the product model and identification numbers. You will need to locate the model and serial number for the pump and record the information in the places provided below.
Page 5
SP-550SD, SP-900SD 26 ft SP-750TD Liquids which can be handled by the Submersible Pump are the follow- ing; clean or slightly contaminated water (max. particle size 0.2”, 5mm or 0.5mm, except the Trash Pump Model # ST-900SD which is 1.4”, 35mm) and soapy water.
Page 6
21” (53cm) and automatically switches off at a water height of approx 2” (5cm) by fixing the float switch cable to the float switch lock (3). The cut-in/cut-out height can be adjusted individually. 4.3 Location and Transport • Please take care that the pump is located in a stable position (especially for automatic operation).
<30mA. • Always check the pump (above all power cable and plug) before each operation. A damaged pump must not be used. It is absolutely neces- sary to have the pump checked by your electrician. • Take care that the electrical connections are made within a dry area, protected from flooding.
• In order to unplug, pull the plug shell not the power cable. • The power cable (1) must not be used for mounting or relocating the pump for submerging or lifting/securing the pump. Fix a rope to the car- rying handle (2).
9. Technical Data SP-550SD SP-750TD Rated Power 550W 750W Max. Delivery Capacity 2905 GPH 2905 GPH 11000 l/h 11000l/h Max. Delivery Height 28 ft 28 ft 8.5m 8.5m Max. Submersion Depth 23 ft 26 ft Contaminated Water with 0.2 in...
trouble shooting guide 10. Trouble-Shooting Guide Problem Probable Cause Remedy Pump is running Air cannot escape, since Open pressure line (e.g. but doesn’t deliver pressure line is closed. kinked pressure pipe.) Air locks in the suction Wait for max 60 seconds base.
Page 11
If you need assistance with the assembly or operation of your Generator please call 1-866-850-6662...
Need help?
Do you have a question about the SP-550SD and is the answer not in the manual?