Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Fluke Manuals
Power Supply
731B
Instruction manual
Specifications; Operating - Fluke 731B Instruction Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
page
of
52
Go
/
52
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Enlarged version
731B
1-7.
SPECIFICATIONS
Output
Voltage
Range
10.0
1.0
1.018
+AE
1.019
+AE
AE
Output
10.0V
dc
1
.OV dc
1.018
to
1.018999V
dc
1.019
to
1.019999V
dc
0
to
999
liV
dc with
1
juV resolution
Output
Accuracy:
Absolute accuracy
at
23°C +1°C
after
30
minute
warm-up
Range
Period
10V
IV
1
.01
8+ -Ae
Ae
30
days
90
Days
1
Year
+
10
PPM
+
10
PPM
+
10
PPM
+
15
PPM
+
15
PPM
+
15
PPM
+
30
PPM
+
30
PPM
+30
PPM
+
2
uV
Transfer Accuracy:
4
Hr
Between
standard
cells
on 1.018V
+
2
ppm
AE
or
1.019V +
AE
ranges:
Between
standard
cell
and
IV
3
ppm
output:
Between 10V
output and standard
5
ppm
ceil
or
IV
output:
Temperature
Coefficient:
Less
than
1
PP^/i/C^
10°Cto45°C
Less than 2
PPM/c",
0''C
to
lO^C and
45°C
to
55°C
Output
Current:
IV,
1.018V,
1.019V
Ranges:
The
Reference
Transfer
Standard
is
designed
to
per-
form
as a
standard
cel!
and
therefore
is
intended to
operate
into a high
impedance on
the IV,
1.018V and
1.019V
ranges
drawing minute
currents.
This impe-
dance
is
usually
infinity
as in
potentiometric
circuits,
or, in
other
applications
should be
at
least
100 Meg-
ohms
to prevent source
loading.
Source
Resistance:
10V Range
<0.0717
IV,
1.018V. 1.019V,
AE
Ranges:
<
1
kS7
Output
Protection:
The output
may
be shorted
indefinitely
without
damage
to instrument.
Line Regulation:
Less
than
1
PPM
for
+10%
line
variation.
Ripple
&
Noise:
Less
than
1
PPM
P-P
dc
to
1
Hz
Less
than
20
juV
RMS
1
Hz
to
1
MHz
Except
<70
juV
RMS @
10V
output
Common
Mode
Rejection:
120
db
at
DC
100
dbateO
Hz
85 db
at
400 Hz
Isolation:
Output
may
be
floated
up
to
500
VDC
between
chassis
ground and
guard.
Calibration
Adjustment:
10 Volt
Range:
The
10
volt
range
is
used
in
applications
where some
degree
of
loading
is
placed
on
the
Reference
Transfer
Standard such
as
a
Kelvin
Varley Divider or other
re-
sistance
networks.
Loading
Effect
on
the
10V
Range
Load
R.
Output Change (PPM)
100 M12
0
10
M17
0.005 «=0
1
M17
.05
0.1
M17
.5
10
KQ
5
Separate
internal
adjustments
for
the 5
output
vol-
tages.
Front
panel
adjustment
common
to
ail
voltages
including the
10.000V
output.
Basic reference adjust-
ments
accessible
from
the front panel.
Temperature/Humidity:
+0°C
to
+55°C
operating.
—
40'^C to
+60°C
non-operating.
Up
to
70%
RH
for
temperatures
<35°C
Shock
&
Vibration:
Meets requirements
of
MIL-T-21200L
1-2
Table of
Contents
Previous
Page
Next
Page
1
...
4
5
6
7
8
9
10
11
Advertisement
Table of Contents
Related Manuals for Fluke 731B
Power Supply Fluke PM2811 User Manual
Programmable power supplies (115 pages)
Power Supply Fluke 415B Instruction Manual
(92 pages)
Power Supply Fluke i50s User Manual
Current probe power supply (24 pages)
Power Supply Fluke 410A User Manual
Direct current power supply (21 pages)
Power Supply Fluke Victoreen 960PS-200 Operator's Manual
Power supply modules (16 pages)
Related Content for Fluke 731B
i50s Specifications
Fluke i50s
415B Electrical Specifications
Fluke 415B
FLK-TI-SBC3B Specifications
FLK-TI-SBC3 Specifications
Victoreen 960PS-200 Specifications
Fluke Victoreen 960PS-200
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL