InstructIons For use
For single patient use (one person) only
Important: read InstructIons and saFety precautIons beFore use.
REMEMBER
Replace YouR Reusable NebulizeR cup eveRY siX MoNths

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LC Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Pari LC Plus

  • Page 1 InstructIons For use For single patient use (one person) only Important: read InstructIons and saFety precautIons beFore use. REMEMBER Replace YouR Reusable NebulizeR cup eveRY siX MoNths...
  • Page 2 brand.
  • Page 3: Indications For Use

    1. to reduce the risk of increased bacterial 7. before use, check paRi Reusable Nebulizer growth, infection, illness, or injury from for proper assembly. all parts should be contamination: thoroughly clean and dry all seated firmly in place.
  • Page 4: Getting Started

    GettInG started check your paRi reusable nebulizer package to ensure items are included. paRi Reusable Nebulizer inspiratory valve cap Nebulizer insert Nebulizer semi-circle alignment Rings Nebulizer outlet Mouthpiece with expiratory valve timestrip ® Nebulizer cup air intake Wing tip tubing ™...
  • Page 5 If activated at the time of first using the PARI reusable see the red line after 3 minutes, press the nebulizer then it will serve as a reminder that the PARI reusable nebulizer can be replaced.
  • Page 6: Nebulizer Set-Up

    Wing-tip tubing to ™ minutes. the warm air from the compressor bottom of paRi reusable nebulizer (Fig. e). will dry the inside of the tubing. use a damp starting treatment: sit in a relaxed, upright cloth to wipe the exterior of the tubing.
  • Page 7 1. Disconnect the tubing from the air intake on 6. air dry or hand dry nebulizer parts on a the bottom of the nebulizer cup. clean, lint-free cloth. Reassemble nebulizer when parts are dry and store.
  • Page 8: Warranty And Return Information

    1.800.Fast.Neb vinegar and 3 parts hot tap water for 1 hour. (327.8632) You can substitute respiratory equipment please be sure to clean and disinfect your paRi disinfectant (like control iii ) for distilled ® reusable nebulizer and place it in a plastic bag white vinegar (follow manufacturer’s...
  • Page 9: Instrucciones De Uso

    InstruccIones de uso Exclusivamente para uso individual (un paciente) Importante: lea las InstruccIones y precaucIones de segurIdad antes de usar el dIsposItIvo. RECUERDE Reemplace la TaZa del NebuliZadoR ReuTiliZable cada SeiS meSeS...
  • Page 10 a...
  • Page 11: Precauciones De Seguridad

    ¿tiene preguntas? 1.800.Fast.neB (327.8632) | parI.com 2...
  • Page 12 B. IntroduccIón Revise el paquete de su nebulizador reutilizable paRi para asegurarse de que todos los elementos estén incluidos. Nebulizador reutilizable paRi Tapa de la válvula de inspiración inserto del nebulizador Semicírculo del nebulizador anillos de alineación Salida del nebulizador boquilla con válvula de expiración...
  • Page 13 ® nebulizador reutilizable paRi. la burbuja paRi entre su dedo y el pulgar. es posible que deba apretarla más de una vez para ADVERTENCIA asegurarse de que haya salido todo el líquido de la burbuja.
  • Page 14 Wing-Tip a la parte inferior del ™ interior de la entubación. use un trapo húmedo nebulizador reutilizable paRi (Fig. e). para limpiar el exterior de la entubación. 5 ¿tiene preguntas? 1.800.Fast.neB (327.8632) | parI.com...
  • Page 15 1. desconecte la entubación de la entrada de 6. deje secar al aire las piezas del nebulizador aire ubicada en la parte inferior de la taza o séquelas a mano sobre un paño limpio y sin del nebulizador.
  • Page 16 3. las piezas del Nebulizador reutilizable paRi (excepto la entubación y la mascarilla) también se pueden desinfectar al hervirlas en un recipiente limpio con agua durante 10 minutos.