Ortech OD-5006 User Manual

Ventilation fan

Advertisement

Quick Links

OD-5006
OD-5006HS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent
power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-
ses, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
Use an on/off switch to operate this fan. See "Connect Wiring" for details.
For model OD-5006HS OD-8011HS
The humidity control and fan can be operated separately. Use a 1 or 2 function wall control. Do not use a dimmer switch
to operate the humidity control or light. See "Connect Wiring" for details.
SENSOR OPERATION
The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable)
increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). The humidity sen-
sor may occasionally turn the fan ON when environmental conditions change. If the fan continuously responds to chang-
ing environmental conditions, "H" (means "humidity") adjustment may be required. This figure is factory-set for about 75%
(Ambient temperature of 25℃).
SENSITIVITY ADJUSTMENT
The "H" has been factory set for most shower applications. However, if the fan is in a tub area or is being used for damp-
ness control, the "H" may need to be increased toward maximum "+". If the control is responding too often to changing
environmental conditions, movement toward less "-" "H" may be required.
To adjust the "H":
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked "H".
3. Carefully rotate the "H" adjustment toward "+" or "-".
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
OD-8011
OD-8011HS
VENTILATION FAN

Advertisement

Table of Contents
loading

Summary of Contents for Ortech OD-5006

  • Page 1 VENTILATION FAN OD-5006 OD-8011 OD-5006HS OD-8011HS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Page 2: Operation

    OPERATION 4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on. 5. Repeat above steps if necessary. When the temperature changes, humidity sensor values will have deviation. TIMER ADJUSTMENT The humidity sensing fan has a “T”...
  • Page 3: Connect Electrical Wiring

    Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown. For OD-5006 OD-8011 BLACK (BLK)
  • Page 4: Service Parts

    INSTALL GRILLE Install ceiling material to complete the ceiling construction. Then, cut around the fan housing. To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly, and position the grille into the housing with the grille springs in the appropriate slots.
  • Page 5 VENTILATEUR OD-5006 OD-8011 OD-5006HS OD-8011HS AVERTISSEMENT PRECAUTION L ENTRETIEN ET LE NETTOYAGE FONCTIONNEMENT Four Model OD-5006HS OD-8011HS...
  • Page 6: Installations Typiques

    FONCTIONNEMENT PLANIFIE VOTRE INSTALLATION INSTALLATIONS TYPIQUES 1. Boîtier monté sur solive en « I » (instructions pour l’assemblage 1) 2. Boîtier monté sur solive (instructions pour l’assemblage 1) 3. Boîtier monté sur poutre triangulée (instructions pour l’assemblage 2) INSTRUCTIONS POUR L’ASSEMBLAGE 1.
  • Page 7 Amenez l’installation domestique de 120 V c.a. à l’emplacement du ventilateur. Utilisez seulement des connecteurs homologués par UL pour relier l’installation domestique à la plaque de connexion. Branchez les fils comme l’illustre le diagramme ci-contre. POUR: OD-5006 OD-8011 NOIR BLANC...
  • Page 8: Installation De La Grille

    INSTALLATION DE LA GRILLE Terminez la préparation du plafond en y installant le matériau. Puis, découpez ce matériau autour du boîtier du ventilateur. Pour fixer la grille au boîtier du ventilateur, pincez les ressorts se trouvant sur les côtés de la grille, puis installez la grille dans le boîtier en insérant les ressorts dans leurs fentes respectives.