ELECTRICAL FEEDER CABLE CONNECTION
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
To connect the supply cable:
•
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
12 .1) .
•
Unscrew the screw "D" and open completely the cable clamp "E" (fig. 12.2).
•
Position the U bolts "F" onto terminal board "G" (fig. 12.2) according to the diagrams
in fig. 12.3.
•
Connect the phase, neutral and earth wires to terminal board "G" according to the
diagrams in fig. 12.3.
•
Strain the feeder cable and block it with cable clamp "E" (by screwing screw "D") .
•
Close the terminal block cover (check the two hooks "A" are correctly hooked) .
NOTE: The earth conductor must be left about 3 cm longer than the others.
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
POWER SUPPLY
230 V
50 Hz
FEEDER CABLE SPECIFICATIONS
Type "H05RR-F" or "H05VV-F"
3 x 4 mm
2
Fig . 12 .1
52
7340 W
A
L1
F
N
L2
D
PE
~
230 V
230 V 50 Hz
230 V
230 V 50 Hz
L
1
N (L
)
2
PE
1
G
2
3
4
5
E
Fig . 12 .2
1
2
3
4
5
Fig . 12 .3
400
L
1
L
2
N
PE