INSTALLING THE THERMOSTAT

DISASSEMBLY

There are two release slots located on the bottom of the thermostat. Gently push
the flat blade of a small screwdriver into one slot at a time and pry upward until
the catch disengages. Carefully swing the thermostat upward and away from the
subbase. (Figure 1)

THERMOSTAT LOCATION

The SMART 1000 should be installed in a location that
represents the ambient space temperature. Do not install
the thermostat in an area where drafts are present, near
the floor, behind doors or on an external wall. Avoid
placing the thermostat in areas where the air movement
is limited, affected by direct sunlight or other areas not
represented by typical of the temperature in the space.

MOUNTING THE SUBBASE

When mounting the SMART 1000 subbase, be aware that drafts
may travel down wall cavities and enter the back of the thermostat
through the control wire hole in the wall. It is important to seal
the hole to prevent any drafts that might affect the internal
temperature sensor.
FIGURE 1