FURNACE SPECIFICATIONS
MODEL
Btuh Input (US) High Fire
Output (US) High Fire
A.F.U.E.
Rated External Static (" w.c.)
Temperature Rise (°F)
High Stage Pressure Switch
Trip Point (" w.c.)
Blower Wheel (D" x W")
Blower Horsepower
Blower Speeds
Max CFM @ 0.5 E.S.P.
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
Transformer (VA)
Heat Anticipator (Amps)
Primary Limit Setting (°F)
Auxiliary Limit Setting (°F)
Rollout Limit Setting (°F)
Gas Supply Pressure
(Natural/Propane) (" w. c.)
Manifold Pressure
(Natural/Propane) High Stage (" w.c.)
Orifice Size (Natural/Propane)
Number of Burners
Vent Connector Diameter (inches)
Shipping Weight (lbs.)
(1)
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: May use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
(3)
See Installation Instructions for appropriate vent diameter, length and number of elbows.
1.
These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2.
For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3.
The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
4.
Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information.
40,000
60,000
32,000
48,000
80%
80%
.20 - .50
.20 - .50
25 - 55
25 -55
-0.70
-0.75
10 X 6
10 x 6
1/3
1/3
4
4
1298
1157
115-60-1
115-60-1
(1)
8.5
8.5
(2)
15
15
40
40
0.7
0.7
210°
150°
120°
120°
300°
300°
7 / 11
7 / 11
3.5 / 10
3.5 / 10
#45 / #55
#45 / #55
2
3
(3 )
4
4
84
88
60,000
80,000
80,000
48,000
64,000
64,000
80%
80%
80%
.20 - .50
.20 - .50
.20 - .50
20 - 50
35 - 65
35 - 65
-0.75
-0.70
-0.75
10 x 8
10X8
10x10
1/2
1/2
1/2
4
4
4
1883
1725
1960
115-60-1
115-60-1
115-60-1
12.9
12.9
12.9
15
15
15
40
40
40
0.7
0.7
0.7
150°
150°
160°
120°
120°
120°
300°
300°
300°
7 / 11
7 / 11
7 / 11
3.5 / 10
3.5 / 10
3.5 / 10
#45 / #55
#45 / #55
#45 / #55
3
4
4
4
4
4
98
106
114
AMS8
100, 000
120, 000
140, 000
80,000
96,000
112, 000
80%
80%
80%
.20 - .50
.20 - .50
.20 - .50
35 - 65
40 - 70
40 - 70
-0.70
-0.80
-0.80
10X10
11x10
11x10
1/2
3/4
3/4
4
4
4
1974
2131
2131
115-60-1
115-60-1
115-60-1
12.9
15.2
15.2
15
15
15
40
40
40
0. 7
0. 7
0. 7
150°
160°
160°
120°
120°
120°
300°
300°
300°
7 / 11
7 / 11
7 / 11
3.5 / 10
3.5 / 10
3.5 / 10
#45 / #55
#45 / #55
#43 / #55
5
6
6
4
4
4
118
130
130
9

Advertisement