Download Print this page

Wiring Diagrams - Amana AMS81405DN Technical Manual

Gas furnace units

Advertisement

WIRING DIAGRAMS

24 VAC
HUMIDIFIER
STEADY ON
0
OFF
1
1 FLASH
2
2 FLASHES
3
3 FLASHES
4 FLASHES
4
5 FLASHES
5
6
6 FLASHES
7
7 FLASHES
C
RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND
COLOR CODES:
YL YELLOW
OR ORANGE
PU PURP LE
GR GREEN
BK BLACK
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
12
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
C
G
R R
W Y
DIAGNOSTIC
LED
FUSE
OR
3
2
1
4
6
5
YL
8
RD
9
7
12
11
10
YL
BR
INTEGRATED
CONTROL MODULE
2
1
115 VAC HOT AND PARK TERMINALS
LINE-H
XFMR-H
HEAT-H
COO L-H
24V
BK
BK
115V
XFMR
WH
DOOR SWITCH
SWITCH LOCATED IN BLOWER
COMPARTMENT ON SOME MODELS
RD
RD
PRIMARY LIMIT
BR
BL
M1
C2
HOT
SURFACE
FLAME
IGNITER
SENSOR
GAS VALVE
PU
PU
PU
ROLLOUT LIMITS
(SINGLE CONTROL ON SOME MODELS)
= NORMAL OPERATION
= CONTROL FAILURE
= SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
= PRESSURE SWITCH STUCK CLOSED
= PRESSURE SW ITCH STUCK OPEN
= OPEN HIGH LIMIT
= FLAME SENSE WITHOUT GAS VALVE
= OPEN ROLLOUT
= LOW FLAME SIGNAL
NOTES:
PK PINK
1. SET HEAT ANT ICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
BR BROW N
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED W HEN SERVIC ING.
WH W HITE
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED , IT MUST BE REPLACED W ITH W IRING MATERIAL HAVING A TEMPERATURE
BL BLUE
RATING OF AT LEAST 105
GY GRAY
4. BLOWER SPEEDS MUST BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION
RD RED
RE QUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE
CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
C
G
TO
Y
MICRO
W
R
AUXILIARY
LIMITS
XFMR (3)
BR
XFMR-H
15 PIN PLUG
ON SOME MODELS
BLOWER COMPARTMENT
LINE-H
BURNER COMPARTMENT
DOOR
24 VAC
SWITCH
HUMIDIFIER
N O
C
YL
WARNING:
DISCONNECT POWER
PRESSURE
YL
BEFORE SERVICING.
SWITCH
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
WH
AND GROUNDED.
BK
TO 115VAC/
OVERCURRENT PROTECTION DEVICE
OR
BK
JUNCTION
BOX
INDUCED DRAFT
BLOWER
TO 115 VAC/ 1/60HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
C. USE COPPER CONDUCTORS ONLY.
INTEGRATED
HUMIDIFIER
CONTROL MODULE
XFMR (6)
GND
GND (8)
GAS
C2
MVC (9)
VALVE
M1
MV (12)
ID BLOWER
PRESSURE
AUXILIARY
SWITCH
LIMIT CO NTROL S
PS (10)
NO
C
PSO (4)
HLI (7)
HLO (1)
AUTO RESET
PRIMARY
LIMIT
RO2 (11)
CO NT ROL
RO1 (5)
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
(SINGLE CONTROL ON SOME MODELS)
24 VAC
40 VA
TRANSFORMER
115 VAC
XFMR-N
FLAME SENSOR
FP (2)
HOT SURFACE
IGNITER
IGN
IGN-N
ID
BLWR
IND
IND-N
COOL-H
CIRCULATOR
BLWR
CIR-N
HEAT-H
LINE-N
JUNCTION BOX
DISCONNECT
L
GND
N
1 Ø /60 HZ P OW ER SUPPLY WITH
LINE-N
GND
LINE H
EQUIPMENT GND
FIELD GND
FIELD SPLICE
SW ITCH (TEMP.)
IGN ITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
0140F00119-C
AMS8

Advertisement

loading