Appendix B: S-Registers - Abocom ISM560 User Manual

Internal fax modem 56k
Hide thumbs Also See for ISM560:
Table of Contents

Advertisement

APPENDIX B: S-REGISTERS

S-Registers, "ATSn=x"
Register
Dec.
S0=
0 - 255
S1=
0 - 255
S2=
0 - 255
S3=
0 - 127
S4=
0 - 127
S5=
0 - 32,
127
Function & Description
Set the number of the rings
required before the modem
automatically answers
a call. Set "S0=0" to disable
auto-answer mode
Count the incoming rings and
store the value to this register.
The value of this register is
incremented with each ring. If
no rings occur over an 8 sec.
interval, this register is cleared.
User can read but should not
change this value
S2 holds the decimal value of
the ASCII character used as the
escape character.
The
default
corresponds to
an ASCII character "+". A
value of 128
to 255 disables the escape
process, i.e.,
no escape character will be
recognized
Hold the decimal value of the
Carriage
Return
character used as the command
line and result code terminator.
Pertain
to
operation only
Hold the decimal value of the
character recognized as a line
feed.The line feed control
character is output after the
carriage
return
character if verbose result code
are used.
Hold the decimal value of the
character
recognized
backspace. The modem will
not recognize the backspace
character if this register is set
to a value greater than 32
- 35 -
value
(043)
<CR>
asynchronous
control
as
a
Default
000
000
043
013
010
008

Advertisement

Table of Contents
loading

Table of Contents