Download Print this page

Miele PT 8407 EL Installations Plan page 12

Hide thumbs Also See for PT 8407 EL:

Advertisement

Equipotential
Connection with male thread
bonding
with washers and nut.
Accessories not included.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all
appropriate national and local regulations.
Vented
Max. nominal air flow in vented mode
Max. permissible pressure loss
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
As relative humidity inside the vent duct can be as high
as 100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Alternative connection: Ducted air intake (from
outside building)
Lid removal exposes live components! For safety
reasons, the pipe connected for central air intake should
be at least 35 7/16" [900 mm] long and secured using
two screws.
Fittings
Without base
2 × clamps
(supplied)
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for floor screed are to be provided on
site.
On concrete platform
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for floor screed are to be provided on
site.
Machine data
Unit width
Machine depth
Unit height
Casing width
Casing depth
Minimum width of delivery access to installation site
Recommended rear wall gap
(measured to front of machine)
Min. wall gap (to rear edge of lid)
Net weight
Dynamic floor load, max.
Average heat dissipation
(dependent on ambient room temperature and
programme selected)
Noise level
Sound pressure level
(measured at a distance of 39 3/8" [1 m] from the
machine and at a height of 63" [1.6 m])
Installation should only be carried out by authorized installers in accordance with all local and national regulations!
Follow installation instructions when installing machine. All rights reserved.
Installation plan: PT 8407 EL
Date: 02.09.2014
Unobstructed air intake into room recommended
(corresponding to 3 times the vent cross-section of
machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
3/8" x 1 3/8"
10 mm × 35 mm
28252 cu ft/h
800 m³/h
0.04 psi
300 Pa
5 7/8"
150 mm
5 7/8"
150 mm
176 °F
80 °C
82.3 in²
531 cm²
6 3/8"
161 mm
6 1/4"
160 mm
1/4" x 1 5/8"
6 mm × 40 mm
3/8" x 2"
10 mm × 50 mm
1/4" x 1 5/8"
6 mm × 40 mm
3/8" x 2"
10 mm × 50 mm
35 5/8"
906 mm
45 7/8"
1164 mm
55 1/8"
1400 mm
35 3/8"
900 mm
41 3/4"
1059 mm
36 1/4"
920 mm
63"
1600 mm
19 3/4"
500 mm
421.08 lbs
191 kg
2170 N
2219.4 BTU/h
650 W
72.8 dB (A)
60 dB (A)
Page: 12

Advertisement

loading