Equipotential
Connection with male thread
bonding
Connection with washers and nut
Accessories to be ordered separately.
If necessary, equipotential bonding with good galvanic contact must be provided in accordance with
all appropriate national and local regulations.
Steam
Steam pressure
connection
Boiling point
Steam supply capacity
Connection thread (on site)
Supply lead Steam valve Length
Steam valve, steam filter and steam fancet must be provided on site.
The steam valve should be installed close to the steam connection. Note installation instructions for
steam-heated Miele tumble dryers.
Condensate
Connection thread (on site)
connection
Steam valve, steam filter and steam faucet must be provided on-site.
Installation of the steam trap needs to allow complete drainage of the heater element during
machine downtime. This means, no condensate is left in the heater element. Installation of an
inverted bucket steam trap is recommended.
Air outlet
Max. nominal air flow in vented mode
Max. permissible pressure loss
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
As relative humidity inside the vent duct can be as high as 100%, suitable measures must be taken
to prevent a backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Alternative connection: Ducted air intake (from outside
building)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
35 7/16" [900 mm] long and secured using two screws.
Installation plan: PT 8807 D
Date: 29-Jan-2015
Recommended unobstructed air intake into room
(corresponding to 3 times the vent cross-section of
machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
3/8" x 1 3/8"
10 mm × 35 mm
3/8"
M 10
87 - 145 psi
600 - 1.000 kPa
329 - 363 °F
165 - 184 °C
156.5 lbs/h
71 kg/h
½" internal thread
19 11/16"
500 mm
½" internal thread
39200 cu ft/h
1110 m³/h
6.3 psf
300 Pa
5 15/16"
150 mm
5 15/16"
150 mm
176 °F
80 °C
82.31 in²
531 cm²
6 5/16"
161 mm
6 5/16"
160 mm