Systems Management - Lenovo x3500 M5 Product Manual

Hide thumbs Also See for x3500 M5:
Table of Contents

Advertisement

The server also supports VMware ESXi installed on a USB memory key. The key is installed in a USB
socket inside the server. The following table lists the virtualization options.
Table 34. Virtualization options - USB memory keys
Part number
Feature
code
00WH140
ATRM
41Y8298
A2G0
00ML233
ASN6
00WH138
ATRL

Systems management

The server contains IMM2.1, which provides advanced service-processor control, monitoring, and an
alerting function. If an environmental condition exceeds a threshold or if a system component fails, the
IMM2.1 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to
the problem. Optionally, the IMM2.1 also provides a virtual presence capability for remote server
management capabilities.
The IMM provides remote server management through the following industry-standard interfaces:
Intelligent Platform Management Interface (IPMI) Version 2.0
Simple Network Management Protocol (SNMP) Version 3
Common Information Model (CIM)
Web browser
The optional Integrated Management Module Advanced Upgrade is required for enabling remote presence
and blue-screen capture features. The remote presence feature provides the following functions:
Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per
pixel colors, regardless of the system state
Remotely accessing the server by using the keyboard and mouse from a remote client
Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping
ISO and diskette image files as virtual drives that are available for use by the server
Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive
The blue-screen capture feature captures the video display contents before the IMM restarts the server
when the IMM detects an operating-system hang condition. A system administrator can use the blue-
screen capture to assist in determining the cause of the hang condition. The following table lists the
remote management option.
Table 35. Remote management option
Part number
Feature code
90Y3901
A1ML
All standard models include basic light path diagnostics, which include system LEDs on the front of the
server (see the following figure) and LEDs near the monitored components (for example, the DIMM error
LED on the system board). The server also offers an optional upgrade to supply another array of light path
diagnostic LEDs on the front of the chassis.
Lenovo System x3500 M5
Description
Blank USB Memory Key 4G SLC for VMware ESXi Downloads
IBM Blank USB Memory Key for VMware ESXi Downloads
USB Memory Key for VMware ESXi 5.1 Update 2
USB Memory Key 4G for VMware ESXi 6.0 Update 1A
Description
Integrated Management Module Advanced Upgrade
Maximum
supported
1
1
1
1
Maximum
supported
1
38

Advertisement

Table of Contents
loading

Table of Contents