Two Way Wireless PIR Outdoor Detector
WL X312
Installation Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WL X312 and is the answer not in the manual?

Questions and answers

Summary of Contents for Risco WL X312

  • Page 1 Two Way Wireless PIR Outdoor Detector WL X312 Installation Instructions...
  • Page 2 Installation Instructions...
  • Page 3: Table Of Contents

    Table of Contents Installation .............................4 Introduction ...........................4 Mounting ............................4 Mounting Considerations ......................4 Wall Mount Installation .......................6 Flat Mounting..........................6 45° angle Mounting (Left side mounting) ..................6 Changing Back Tamper position....................7 Back Tamper Terminal Wiring.....................7 Configuration Parameters ......................7 Detection Length Adjustment .....................8 Walk test............................9 LEDs Display ..........................9 Operational Modes........................9...
  • Page 4: Installation

    Installation Introduction RISCO Group's WL X312 is a unique detector with signal processing based on two Passive Infrared (PIR) channels. The WL X312 has an adjustable detection range. The detector is compatible with all RISCO Group Wireless and Hybrid systems.
  • Page 5 Installing the WL X312 detector in challenging situations In the following situations, rapid and significant infrared radiation changes can happen in both PIR channels together, resulting in false alarms and therefore care should be taken. 1. Situations in which metal and/or glass objects measuring over 70cm (2’4”) in height from the ground are in the field of view of the detector (cars, metal gates, shutters, metal walls, windows, etc.)
  • Page 6: Wall Mount Installation

    Wall Mount Installation Figure 1 Figure 2 NOTE The installation knockouts numbering are marked on the back plate. 1. Open the WL 312 front cover (unlock C1, Figure 1). 2. Release internal base (unlock I1, Figure 3. Select mounting installation as follows: Flat Mounting: Open knockouts on external base (Figure •...
  • Page 7: Changing Back Tamper Position

    Figure 5 Changing Back Tamper position: Left Side The back tamper is by default secured on the right Tamper side of the internal base (Rear view). If you wish to move it to the left side (rear view), do the following Right Side (Figure 5): Tamper...
  • Page 8: Detection Length Adjustment

    Detection Range Adjustment Slide the moving PIR to the desired position, see figure 6. The range of the lower detection area determines the detection range. The upper PIR is fixed and its detection area is parallel to the ground at all times. The lower detection area changes from 2m to 12m depending on the location of the moving PIR.
  • Page 9: Walk Test

    Walk test Two minutes after applying power, walk test the protected area to verify proper operation. Adjust the moving PIR for required detection range and reliability. NOTE: When there is traffic in the detection area the detection area may increase due to environmental thermal conditions, therefore it is recommended to increase the detection area from 1.5m to 2m away from the traffic.
  • Page 10: Standard Swivel Installation (Optional)

    CAUTION NOTICE Changes or modifications not expressly approved by RISCO Group may void the user’s authority to operate this equipment. Simultaneous transmissions from two different units may cause message interference resulting in loss of information. The communication quality of this unit may be affected by its surrounding environment. Nearby electrical equipment may interfere with its normal operation.
  • Page 11 Figure 9 NOTE: Do not open or close the Swivel Assy Screw since it is used for connecting the swivel parts only (factory tightened). Secure external base to swivel with two screws fastened trough knockouts S1 and S2 (Figure 9). Insert the supplied angle locking screw from the external base through the angle locking screw knockout S3 on the external base to the standard swivel (Figure 9).
  • Page 12: Replacing Lenses

    NOTE: ° When marks on the two movable parts are aligned (Figure 9), the Standard Swivel is in 0 vertical/horizontal ° position. Each click from this position represents shifting of 5 in vertical/horizontal position. 10. Close the front cover (Lock C1, Figure 1) and walk test the detector. NOTE: The screw has to pass through the External Base and locked to the swivel.
  • Page 13: Technical Specification

    * PIR technology is limited in harsh environmental conditions. RF immunity According to EN50130-4 * Specifications are subject to change without prior notice. Ordering Information Model Description WL X312 Two way WatchOUT Wireless PIR 868/433 Accessory Kits Model Description Weight RA300B Barrier Swivel Kit 0.1 Kg (0.23 lb)
  • Page 14 Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment which are not expressly approved by the party responsible for compliance (RISCO Group's.) could void the user's authority to operate the equipment. FCC ID: JE4AGILITY Valid for model: WL X312...
  • Page 15 RISCO Group Limited Warranty RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product.
  • Page 16 Contacting RISCO Group RISCO Group is committed to customer service and product support. You can contact us through our website (www.riscogroup.com) or at the following telephone and fax numbers: United Kingdom Tel: +44-161-655-5500 Tel: +1-631-719-4400 technical@riscogroup.co.uk support-usa@riscogroup.com Italy Brazil Tel: +39-02-66590054 Tel: +55-11-3661-8767 support@riscogroup.it...