The iWISE 815DTG3/825DTG3 detectors are the ultimate motion detectors for professional installations, incorporating both Anti-Mask and Anti-Cloak™ Technologies (ACT™), adhering to new environmentally friendly guidelines.
iWISE 815DTG3/825DTG3 detectors are available in 15m and 25m models, and include built-in end-of-line (EOL) resistors to simplify installation.
Note: If a back tamper is to be used it is mandatory to screw the tamper back plate to the wall (or wall corner).
Mounting Height | L - LONG | S - SHORT |
For 815DTG3 | ||
2.1m-2.7m (6'11"-8'10") | 15m (50') | 6m (20') |
For 825DTG3 | ||
1.8m-2.0m (5'11"-6'7") | 25m (82') | 8m (26') |
Note: For Corridor installations, select position to 'LONG' and mount the detector at 2.5m/8'2" height.
On the face of the Microwave, you will find a colored dot, this represents the Microwave channel. When installing two detectors in near locations, it is recommended that these dots (channels) are not of the same color. Example: Two Red should be avoided
Note: Reset the detector after each change made to the settings.
Terminal | Description |
- 12 + | 12VDC Input |
ALARM | N.C. Relay |
TAMPER | N.C. Tamper switch |
FAULT/AM | Normally Closed Relay: The FAULT/AM relay opens in the following events:
|
LED | LED operation remote control |
When an "Activation Signal"** is applied to the LED input terminal, all LEDs will be disabled. LEDs are enabled if nothing is connected (unless LED jumper is OFF) or 0V/12V is applied (according to the LED/SET Input Jumper position, 12V or 0V). | |
SET | Remote SET/UNSET control |
SET:If an "Activation Signal"** is applied, anti-mask detection is disabled (for Grade 2 configuration). UNSET: If nothing is connected or 0V/12V is applied (according to the LED/SET Input Jumper position, 12V or 0V) anti-mask detection is enabled (see also "Green Line" and "Remote Self Test" |
**Activation Signal-
If 12VDC is applied, and the LED/SET Input Jumper is on 12v position
- Or -
0V is applied and LED/SET Input Jumper is on 0V position
Jumper | Function |
SW1-1: LED | Used to determine the operation of the detector's LEDs |
ON: (Default) | LEDs are enabled, allowing LED control via the LED input terminal |
OFF: | LEDs are disabled |
SW1-2: ACT | Used to determine if ACT mode is enabled or disabled |
ON | ACT Enabled Do not use ACT™ mode if you are expecting that there will be moving objects outside the required protected area, a corridor for example. |
OFF (Default) | ACT Disabled. |
SW1-3: Green Line The iWISE 815DTG3/825DTG3 includes a Green Line feature that follows environmental guidelines by avoiding surplus emission. This feature disables the MW channel when the alarm system is "Unset", thus eliminating surplus MW emission while the premises is occupied. | |
ON | Green Line feature is enabled: To deactivate the MW module in "UNSET" period, the LEDs must also be remotely disabled by the LED terminal. Note: When 'Green Line' is on (Microwave off), the detector will still activate (PIR only) |
OFF (Default) | Green Line feature in disabled: MW is constantly in use. |
SW1-4: Self Test | Used to test detection technologies. |
ON | (Local Self Test): If there is no alarm detection in the PIR channel fora period of one 1 hour, the detector will self-test. If the local self test fails, the FAULT/AM Relay will activate. |
OFF (Default) | (Remote Self Test): Remote Self Test is activated when the SET terminal is switched from SET to UNSET mode. For remote self test pass, the Alarm Relay will activate for 5 seconds. |
J1 - Alarm EOL J2 - Tamper EOL J3 - FAULT/AM EOL | Jumpers J1 and J2 allow the selection of Tamper and Alarm resistance (1K, 2.2K, 4.7K, 5.6K, 6.8K) according to the control panel (see Figure 3). Jumper J3 allows the selection of 12K for Fault/Anti-Mask. Follow the terminal block connection diagram in Figure 3 when connecting the detector to a Double/Triple End Of Line (DEOL/TEOL) Zone. |
J4 - LED/SET INPUT | Used to determine the polarity of the external input. |
![]() | See Terminal Wiring section, LED and SET Terminals |
![]() | See Terminal Wiring section, LED and SET Terminals |
After applying power to the detector, close the cover within 2 minutes as after this period AM initialization will start.
MW range adjustment (Figure 4)
LED | State | Description |
Yellow | On | PIR detection |
Flashing | Trouble in PIR channel | |
Green | On | MW detection |
Flashing | Trouble in MW channel | |
Red | On | ALARM |
Flashing | Fault / Anti-Masking detection Note: Anti Masking detection is operational in "Unset" mode only (see Terminal Wiring section, SET terminal). | |
All LEDs | Flashing (consecutively) | At power-up, the LEDs will flash consecutively until the end of the warm-up period (2-3 minutes). At the end of the warm-up period the RED LED will continue to flash until the end of AM initiation. |
Note: AM and Trouble indications continue until masking is removed or trouble is corrected.
Electrical | |
Current consumption | 16mA at 12VDC (Typical) 41mA at 12VDC (max.) |
Voltage requirements | 9 -16VDC*** |
Alarm contacts | 24VDC, 0.1A |
Tamper contacts | 24VDC, 0.1A |
FAULT/AM contacts | 24VDC, 0.1A |
Environmental | |
RF immunity | According to EN50130-4 |
Operating temperature | -10C to 55C (14F to 131F) |
Storage temperature | -20C to 60C (-4F to 140F) |
Optical | |
Filtering | White Light Protection |
Physical | |
Size | 127.6 x 64.2 x 46.6 mm (5 x 2.5 x 1.84 in.) |
Weight | 120 gr. (4.2 oz.) |
*** Power to be supplied by 5A max. power source using safety approved wires, with a min Gauge of 20AWG.