Kenwood KDC-1032 Service Manual page 6

Hide thumbs Also See for KDC-1032:
Table of Contents

Advertisement

KDC-1032/132/132CR
KDC-133/233/234SGY
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
56
LO/EJ
57
M-STOP
58
M-RST
59
M-MUTE
60
RESET
61
REMO
62
R-CLK
63
NC
64
LOS SW
65
KEY-REQ
66
8EJE SW
67
VSS0
68
VDD1
69
X2
70
X1
71
IC
72
XT2
73
XT1
74
VDD0
75
AVREF0
76
S-METER
77
NOISE
78
PHONE
79
NC
80
AVCONT
Truth value table
q Destination
TYPE2 (pin29)
TYPE1 (pin30)
0
0
0
0
1
1
1
1
6
I/O
Application
I/O
CD mechanism Loading/Eject switching
O
CD mechanism Stop output
O
CD mechanism Reset output
I
CD mechanism mute input
System µ-com reset input
I
I
Remote controller input
I
RDS clock input
-
I
CD mechanism Loading SW detection
Key input detection
I
(Connection with pin 11 L-DATAL)
I
12cm DISC detection
-
-
-
MAIN X'tal oscillation circuit
-
MAIN X'tal oscillation circuit
-
TEST
-
NC
-
VDD
-
AD converter reference voltage
-
(Connection to pin 80 AVCONT)
I
S-meter input
I
NOISE detection (FM)
I
2way Mute
-
Not used (output L)
O
AD reference voltage control
TYPE0 (pin31)
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
Truth value table
H: Eject, L: Loading
H: CD ON, L: Stop
H: Normal, L: Mechanism reset
H: Mute OFF, L: Mute ON
L-output for models without RDS
Not used (output L)
H: No DISC, L: DISC IN (Loading start)
H: No key input
L: Key input (Started to read Edge Key Data)
L: 12cm DISC
4.19MHz X'tal connection
4.19MHz X'tal connection
Open
VDD connection
2.5V or more: NAVI mute, 1.0V or less: TEL mute
L-output to the model without Phone mute
H: When AD converter is used
The same timing as P. ON
DESTINATION
K
KDC-1032/132/132CR
-
-
E
KDC-234SGA/334SA/334SAY/334SG/334SGY
-
-
-
-
M
KDC-132/233
-
-
J
RDT-111
Processing Operation Description
MODEL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-133/233Kdc-234sgyKdc-132/cr

Table of Contents