8.5

General Installation Diagram with Duct type

units

Warning!
Danger of breakdowns or malfunction.
Observe the minimum assembly distances
indicated in Figure 8.3 and 8.5.
Fig. 8.3 General diagram of the installation and the minimum
assembly distances.
Legend
1
Indoor Unit
2 Outdoor Unit
3 Pipe for draining the condensed water
E Side separation opposite side connections (minimum 10 cm)
F Rear separation (minimum 10 cm)
G Side separation connections side (minimum 15 cm)
H Front separation (minimum 60 cm)
Multi Split Type Installation Manual
Fig. 8.4 Minimum assembly distances (Cassette unit).
MODEL
A
VA 6-035 MXNHKI
1000
VA 6-050 MXNHKI
1000
Table 8.1 Indoor unit minimum assembly distances.
Fig. 8.5 Minimum assembly distances (Duct type unit).
MODEL
A
VA 6-035 MXNHDI
200
VA 6-050 MXNHDI
200
Table 8.2 Indoor unit minimum assembly distances.
Installation 8
B
C
D
1000
1000
1000
1000
1000
1000
B
C
D
200
500
500
200
500
500
EN
11