For the user User Manual Air Conditioner - climaVAIR Split Type VA 6-020 MXNHI VA 6-025 MXNHI VA 6-035 MXNHI VA 10-020 MXNHI VA 10-025 MXNHI VA 10-035 MXNHI...
Your Safety 1 Extreme Operating Conditions 2 Extreme Operating Conditions Your Safety This unit has been designed to operate within the range Symbols used of temperatures indicated on Figure 2.1. Ensure that these ranges are not exceeded. Danger! Direct danger for life and health. EATING OOLING Outdoor...
3 Identification of the Unit 4 Declaration of Conformity 5 Description of the Unit Identification of the Unit Description of the Unit This manual is valid for the Split Murales series. In order This unit is comprised of the following elements: to know the specific model of your unit please refer to - Outdoor unit.
Description of the Unit 5 Technical Specifications TECHNICAL PICTORIAL DESCRIPTION SPECIFICATIONS SYMBOL Heat pump The equipment is reversible. It allows cooling or heating the rooms as desired. Refrigerant R-410A Refrigerant free of chlorine, ecological and environmentally friendly with a transfer capacity greater than R 407 C or than R22, providing far better COP levels.
6 Initial Settings Initial Settings Clock Settings Use the remote controller to adjust the unit clock, see Fitting the Remote Controller Batteries Figure 6.2. Insert the batteries R-03 (7#), as described below (see • Press the CLOCK button. Figure 6.1). The “AM”...
Operating Instructions 7 Operating Instructions Identification of Functions General Safety Considerations during Use 7.2.1 Remote Controller Buttons Danger of injury and physical damage! - Do not let children play with the air conditioning unit. The unit is not designed for use by children. - Do not connect the equipment whilst using insecticides or pesticides.
7 Operating Instructions 7.2.2 Display Indicators Advice on how to use the Remote Controller Follow the recommendations below as to how to use the remote controller: - When in use, direct the head of the signal transmitter directly to the outdoor unit receiver. - Keep the distance between the transmitter and the receiver within 7 m.
Operating Instructions 7 Selection of the Operation Mode 7.5.2 Cooling Mode (COOL) In cooling mode (COOL), the air conditioning unit only 7.5.1 Automatic Mode (AUTO) allows cooling. In automatic mode (AUTO) the air conditioning unit automatically selects the cooling (COOL) or heating Note! (HEAT) mode in accordance with the actual ambient In cooling mode it is recommendable to direct...
7 Operating Instructions • Select the cooling operation mode (COOL). 7.5.3 Dehumidifying Mode (DRY) • Press the TEMP buttons to select the temperature In dehumidifying mode (DRY), the air conditioning unit setting. operates by removing the humidity from the When pressing the TEMP buttons, the temperature atmosphere.
Operating Instructions 7 • Select the dehumidifying mode (DRY). 7.5.4 Fan Mode (FAN) • Press the TEMP buttons to select the temperature In fan mode (FAN) the unit does not operate in the setting. following modes: When pressing the TEMP buttons, the temperature - cooling mode (COOL).
7 Operating Instructions • Select the fan operation mode (FAN). 7.5.5 Heating Mode (HEAT) • Press the FAN button to select the fan speed. In heating mode, the air conditioning only allows Each time the FAN button is pressed, the fan speed heating.
Operating Instructions 7 • Press the FAN button to select the fan speed. Setting the direction of the airflow Each time the FAN button is pressed, the fan speed The direction of the airflow can be set in vertical and will be modified as shown in Figure 7.17.
7 Operating Instructions 7.6.1 Vertical Airflow 7.6.2 Horizontal Airflow • Press the SWING UP/DOWN button to direct the • Press the SWING LEFT/RIGHT button to direct the airflow upwards or downwards. airflow to the left or right. The vertical slat will be directed in accordance with The horizontal deflectors are directed in accordance the positions allowed for each operation mode.
Operating Instructions 7 Special Function Selection Note! The HEALTH indicator (IONISER) will light when 7.7.1 Ionizer Operation (HEALTH) the indoor unit fan does not function even if the The anion generator of the air conditioning unit has the anion generator is not operating. following functions: - To generate anions to neutralise the quantity of cations and anions in the air.
7 Operating Instructions • Press the HEALTH FLOW button again to cancel the 7.7.3 SLEEP function ionised airflow function. The COOL, DRY, HEAT modes can be set during the Both the inlet and outlet grates will remain open nighttime hours to avoid an excessive increase or operating in the mode in which the unit was decrease in the temperature.
Operating Instructions 7 7.7.4 TIMER ON/OFF Function (CONNECTION/ DISCONNECTION USING TIMER) The unit can be connected/disconnected using the timer. Fig. 7.21 Working method of the SLEEP function in COOL, DRY mode. Legend T 1 Configured temperature t o Start of the SLEEP function In HEAT mode The ambient temperature decreases 2ºC in relation to the configured one to ensure that the temperature does...
7 Operating Instructions • Press the HOUR buttons to programme the desired time: When pressing the HOUR buttons, the time configuration will increase or decrease by 1 minute. If the HOUR buttons are kept pressed, the time will increase or decrease rapidly. The time can be set within an interval of 24 hours.
Indicators of the indoor unit 8 Advice for saving Energy 9 Indicators of the indoor unit Ambient Temperature when absent During heating mode, an economic saving is made by keeping the ambient temperature at approx. 5ºC lower than the normal temperature. A reduction which exceeds these 5º...
The table below describes a series of problems with their possible causes and solutions, see Table 9.1. If these solutions do not solve the problem contact your usual installer or call your nearest SAT Vaillant service. SYMPTOMS POSSIBLE CAUSES POSSIBLE SOLUTION The system does not work at all (the The selector is set to "O"...
Do not use petrol, solvents or polishes when cleaning the unit. Note! We advise you to contact a reliable air conditioner specialist or the Vaillant Official 11.1 Cleaning the Indoor Unit Technical Service to contract a preventative • Wipe the outer part of the unit with a dry cloth.
12 Storage over a prolonged Period 13 Product Decommissioning 12 Storage over a prolonged Period 13 Product Decommissioning If you do not intend to use the unit over a period of Danger of injury and physical damage! time: When disposing of the product, ensure that the •...