Generator; Nominal 12Vdc Output - Predator 2000 Owner's Manual & Safety Instructions

Table of Contents

Advertisement

5. Allow the Engine to run for
several seconds.
Wait for the OUTPUT light to light up.
6. Then, move the Combination Switch
slowly to its RUN position.
Note: Moving the Combination Switch
too fast could stall the Engine.
IMpORTANT: Allow the Engine
to run at no load for five minutes
with no load after each start-up so
that the Engine can stabilize.
Break-in period:
a. Breaking-in the Engine will help to ensure proper equipment and Engine operation.
b. The break-in period will last about 25 hours of use.
DO NOT exceed 75% of the Generator's running wattage during this period.
• Change the engine oil after this period.
Under normal operating conditions subsequent maintenance follows
the schedule explained in the MAINTENANCE section.

Nominal 12VDC Output

1. Do not use any 120VAC outlet
while using the 12VDC outlet.
2. Move the Economy (ESC) Switch
to the OFF position.
3. Only use the 12VDC receptacle to
charge a 12 volt lead-acid type battery
using an appropriate charge controller.
(Battery and controller not included.)
The 12VDC output is not regulated.
4. Do not connect any device to the 12VDC
terminal that draws more than 8 amps.
5. If this 12VDC circuit protection is tripped,
reduce the load, and press
the Reset Button next to the outlet.
Page 10
5
L O W
6
For technical questions, please call 1-888-866-5797.
p U T
O U T
A D
R L O
O V E
O I L
O F F
R U N
T
S T A R
Move
Slowly
Reset
Button
12VDC
Receptacle
ITEM 62523